» Articles » PMID: 34487310

Evaluation of Complex Congenital Heart Disease with Prospective ECG-gated Cardiac CT in a Single Heartbeat at Low Tube Voltage (70 kV) and Adaptive Statistical Iterative Reconstruction in Infants: a Single Center Experience

Overview
Publisher Springer
Specialty Radiology
Date 2021 Sep 6
PMID 34487310
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study is to evaluate the radiation dose, image quality, and diagnostic accuracy of prospective ECG-gated cardiac CT at 70 kV and adaptive statistical iterative reconstruction (ASIR), with a single source, 512 slice MDCT in the diagnosis of complex congenital heart disease in infants. We retrospectively evaluated 47 infants (ages 1 day to 353 days) with prospective ECG-gated cardiac CT that was performed on a single source 512 slice CT at low tube voltage (70 kV) using a wide detector aperture, adaptive statistical iterative reconstruction algorithm (ASIR), and specific reconstruction software reducing coronary motion artifacts (SnapShot Freeze). All cardiac images were obtained during the first pass of contrast material through the anatomic structures of interest and the targets for the center of the acquisition window were set 45% of the R-R interval during one cardiac cycle without sedation and breath-hold. The median effective dose measured in our study was 0.64 ± 0.16 mSv. The average subjective overall image quality score was 4.34 ± 0.31 (range 3-5). For the determination of objective image quality, Mean Noise (HU), SNR, and CNR values ​​emerged as 20.8, 28.7(for pulmonary artery), and 27.1, respectively. Diagnostic accuracy was 100% for the main purposes for the main clinical indication. During cardiac CT examination, pathologies in addition to cardiac anomalies were found in 9/47 of cases (7 severe airway obstructions,1 posterior diaphragmatic hernia, 1 vertebral anomaly). Prospective ECG-gated cardiac CT scan at 70 kV and ASIR in infants with complex CHD provides low radiation dose (submillisievert) in a single heartbeat with a good objective and subjective image quality. It also provides important benefits in the diagnosis of additional pathology.

Citing Articles

A Review of Factors Affecting Radiation Dose and Image Quality in Coronary CTA Performed with Wide-Detector CT.

Fan Y, Qin T, Sun Q, Wang M, Liang B Tomography. 2024; 10(11):1730-1743.

PMID: 39590936 PMC: 11598146. DOI: 10.3390/tomography10110127.


Comparison and Agreement between Cardiovascular Computed Tomography-Derived Mid-Diastolic and End-Diastolic Ventricular Volume in Patients with Congenital Heart Disease.

Cheong D, Alloah Q, Fishbein J, Rajagopal H Pediatr Cardiol. 2024; 46(4):844-852.

PMID: 38689021 DOI: 10.1007/s00246-024-03504-x.


Application of double low-dose mode in left atrial-pulmonary venous computed tomography angiography.

Zhang C, Zhang W, Shi K, Chen J Sci Rep. 2023; 13(1):21563.

PMID: 38057356 PMC: 10700435. DOI: 10.1038/s41598-023-48973-x.

References
1.
Wiant A, Nyberg E, Gilkeson R . CT evaluation of congenital heart disease in adults. AJR Am J Roentgenol. 2009; 193(2):388-96. DOI: 10.2214/AJR.08.2192. View

2.
Hoffman J, Kaplan S . The incidence of congenital heart disease. J Am Coll Cardiol. 2002; 39(12):1890-900. DOI: 10.1016/s0735-1097(02)01886-7. View

3.
MOLLER J, Taubert K, ALLEN H, Clark E, Lauer R . Cardiovascular health and disease in children: current status. A Special Writing Group from the Task Force on Children and Youth, American Heart Association. Circulation. 1994; 89(2):923-30. DOI: 10.1161/01.cir.89.2.923. View

4.
Siripornpitak S, Pornkul R, Khowsathit P, Layangool T, Promphan W, Pongpanich B . Cardiac CT angiography in children with congenital heart disease. Eur J Radiol. 2011; 82(7):1067-82. DOI: 10.1016/j.ejrad.2011.11.042. View

5.
Le Roy J, Vernhet Kovacsik H, Zarqane H, Vincenti M, Abassi H, Lavastre K . Submillisievert Multiphasic Coronary Computed Tomography Angiography for Pediatric Patients With Congenital Heart Diseases. Circ Cardiovasc Imaging. 2019; 12(2):e008348. DOI: 10.1161/CIRCIMAGING.118.008348. View