The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103

Overview
Journal Ann ICRP
Date 2007 Dec 18
PMID 18082557
Citations 1907
Affiliations
Soon will be listed here.
Abstract

These revised Recommendations for a System of Radiological Protection formally replace the Commission's previous, 1990, Recommendations; and update, consolidate, and develop the additional guidance on the control of exposure from radiation sources issued since 1990. Thus, the present Recommendations update the radiation and tissue weighting factors in the quantities equivalent and effective dose and update the radiation detriment, based on the latest available scientific information of the biology and physics of radiation exposure. They maintain the Commission's three fundamental principles of radiological protection, namely justification, optimisation, and the application of dose limits, clarifying how they apply to radiation sources delivering exposure and to individuals receiving exposure. The Recommendations evolve from the previous process-based protection approach using practices and interventions by moving to an approach based on the exposure situation. They recognise planned, emergency, and existing exposure situations, and apply the fundamental principles of justification and optimisation of protection to all of these situations. They maintain the Commission's current individual dose limits for effective dose and equivalent dose from all regulated sources in planned exposure situations. They reinforce the principle of optimisation of protection, which should be applicable in a similar way to all exposure situations, subject to the following restrictions on individual doses and risks; dose and risk constraints for planned exposure situations, and reference levels for emergency and existing exposure situations. The Recommendations also include an approach for developing a framework to demonstrate radiological protection of the environment.

Citing Articles

Patient Shielding in Ultra-High-Resolution Cone-Beam CT of the Upper Extremity with a Twin Robotic X-Ray System.

Kunz A, Weick S, Grunz J, Toussaint A, Razinskas G, Richter A Diagnostics (Basel). 2025; 15(5).

PMID: 40075843 PMC: 11898918. DOI: 10.3390/diagnostics15050596.


In silico analysis of radiation-induced double-strand breaks by internal ex vivo irradiation of lymphocytes for 45 alpha- and beta/gamma-emitting radionuclides.

Salas-Ramirez M, Lassmann M, Eberlein U EJNMMI Res. 2025; 15(1):21.

PMID: 40063302 PMC: 11893945. DOI: 10.1186/s13550-025-01214-w.


Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty.

Sequeira S, Brett A, Nessler J, Frye B, Mont M Arthroplast Today. 2025; 32:101617.

PMID: 40008011 PMC: 11851197. DOI: 10.1016/j.artd.2025.101617.


Dosimetry Testing for a New In Vivo X-ray Fluorescence Measurement System.

Burgos C, Read D, Grier T, Khan M, Weisskopf M, Taylor K Health Phys. 2025; 128(4):273-278.

PMID: 39999410 PMC: 11864586. DOI: 10.1097/HP.0000000000001839.


On the automated radiosynthesis of pharmaceutical grade [Ga]Ga-Pentixafor, its pre-clinical evaluation, clinical application and radiation dosimetry aspects.

Menon S, Sahu S, Mitra A, Chakraborty A, Malhotra G, Kamaldeep Sci Rep. 2025; 15(1):6476.

PMID: 39987209 PMC: 11846852. DOI: 10.1038/s41598-024-84096-7.