» Articles » PMID: 29121500

Validation of a Salmonella Loop-mediated Isothermal Amplification Assay in Animal Food

Overview
Date 2017 Nov 10
PMID 29121500
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Loop-mediated isothermal amplification (LAMP) has emerged as a promising alternative to PCR for pathogen detection in food testing and clinical diagnostics. This study aimed to validate a Salmonella LAMP method run on both turbidimetry (LAMP I) and fluorescence (LAMP II) platforms in representative animal food commodities. The U.S. Food and Drug Administration (FDA)'s culture-based Bacteriological Analytical Manual (BAM) method was used as the reference method and a real-time quantitative PCR (qPCR) assay was also performed. The method comparison study followed the FDA's microbiological methods validation guidelines, which align well with those from the AOAC International and ISO. Both LAMP assays were 100% specific among 300 strains (247 Salmonella of 185 serovars and 53 non-Salmonella) tested. The detection limits ranged from 1.3 to 28 cells for six Salmonella strains of various serovars. Six commodities consisting of four animal feed items (cattle feed, chicken feed, horse feed, and swine feed) and two pet food items (dry cat food and dry dog food) all yielded satisfactory results. Compared to the BAM method, the relative levels of detection (RLODs) for LAMP I ranged from 0.317 to 1 with a combined value of 0.610, while those for LAMP II ranged from 0.394 to 1.152 with a combined value of 0.783, which all fell within the acceptability limit (2.5) for an unpaired study. This also suggests that LAMP was more sensitive than the BAM method at detecting low-level Salmonella contamination in animal food and results were available 3days sooner. The performance of LAMP on both platforms was comparable to that of qPCR but notably faster, particularly LAMP II. Given the importance of Salmonella in animal food safety, the LAMP assays validated in this study holds great promise as a rapid, reliable, and robust method for routine screening of Salmonella in these commodities.

Citing Articles

Exploring animal food microbiomes and resistomes via 16S rRNA gene amplicon sequencing and shotgun metagenomics.

Ge B, McDonald R, Yang Q, Domesle K, Sarria S, Li X Appl Environ Microbiol. 2025; 91(2):e0223024.

PMID: 39840975 PMC: 11837513. DOI: 10.1128/aem.02230-24.


Surface monitoring of L. monocytogenes by real-time fluorescence and colorimetric LAMP.

Abalo M, Lamas A, Teixeira C, Prado M, Garrido-Maestu A Appl Microbiol Biotechnol. 2024; 108(1):510.

PMID: 39531058 PMC: 11557679. DOI: 10.1007/s00253-024-13318-9.


Research progress of loop-mediated isothermal amplification in the detection of Salmonella for food safety applications.

Zhuang L, Gong J, Zhang P, Zhang D, Zhao Y, Yang J Discov Nano. 2024; 19(1):124.

PMID: 39105889 PMC: 11303641. DOI: 10.1186/s11671-024-04075-9.


Salmonella detection with LAMP and qPCR and identification of serovars of interest by multiplex qPCR in poultry carcasses.

da Silva E, de Oliveira C, Ribeiro L, Casas M, Pereira J, Possebon F Braz J Microbiol. 2023; 54(3):2173-2182.

PMID: 37582950 PMC: 10484893. DOI: 10.1007/s42770-023-01095-y.


A novel loop-mediated isothermal amplification-lateral flow dipstick method for detection.

Liu W, Lu G, Wang Y, Chen Z, Gao Y, Yin Z Front Microbiol. 2023; 14:1094600.

PMID: 37032891 PMC: 10076779. DOI: 10.3389/fmicb.2023.1094600.