» Articles » PMID: 28475981

Soft Tissue Artifact Causes Significant Errors in the Calculation of Joint Angles and Range of Motion at the Hip

Overview
Journal Gait Posture
Specialty Orthopedics
Date 2017 May 6
PMID 28475981
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

Soft tissue movement between reflective skin markers and underlying bone induces errors in gait analysis. These errors are known as soft tissue artifact (STA). Prior studies have not examined how STA affects hip joint angles and range of motion (ROM) during dynamic activities. Herein, we: 1) measured STA of skin markers on the pelvis and thigh during walking, hip abduction and hip rotation, 2) quantified errors in tracking the thigh, pelvis and hip joint angles/ROM, and 3) determined whether model constraints on hip joint degrees of freedom mitigated errors. Eleven asymptomatic young adults were imaged simultaneously with retroreflective skin markers (SM) and dual fluoroscopy (DF), an X-ray technique with sub-millimeter and sub-degree accuracy. STA, defined as the range of SM positions in the DF-measured bone anatomical frame, varied based on marker location, activity and subject. Considering all skin markers and activities, mean STA ranged from 0.3cm to 5.4cm. STA caused the hip joint angle tracked with SM to be 1.9° more extended, 0.6° more adducted, and 5.8° more internally rotated than the hip tracked with DF. ROM was reduced for SM measurements relative to DF, with the largest difference of 21.8° about the internal-external axis during hip rotation. Constraining the model did not consistently reduce angle errors. Our results indicate STA causes substantial errors, particularly for markers tracking the femur and during hip internal-external rotation. This study establishes the need for future research to develop methods minimizing STA of markers on the thigh and pelvis.

Citing Articles

Reducing soft tissue artefacts through projection of markers and microwave imaging: An exploratory study.

Radhakrishnan V, Robinson M, Fiorentino N, Patil S, Pelah A Sci Rep. 2025; 15(1):7679.

PMID: 40044738 PMC: 11883034. DOI: 10.1038/s41598-025-89586-w.


Reliability and validity of a video-based markerless motion capture system in young healthy subjects.

Wang Z, Chen H, Yue L, Zhang J, Sun H Heliyon. 2025; 11(4):e42597.

PMID: 40040988 PMC: 11876916. DOI: 10.1016/j.heliyon.2025.e42597.


Reliability of artificial intelligence-driven markerless motion capture in gait analyses of healthy adults.

Schoenwether B, Ripic Z, Nienhuis M, Signorile J, Best T, Eltoukhy M PLoS One. 2025; 20(1):e0316119.

PMID: 39841651 PMC: 11753651. DOI: 10.1371/journal.pone.0316119.


Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion.

Johnson C, Ruh E, Frankston N, Charles S, McClincy M, Anderst W J Biomech Eng. 2024; 146(12).

PMID: 39262043 PMC: 11500802. DOI: 10.1115/1.4066466.


Gait signature changes with walking speed are similar among able-bodied young adults despite persistent individual-specific differences.

Winner T, Rosenberg M, Berman G, Kesar T, Ting L Sci Rep. 2024; 14(1):19730.

PMID: 39183361 PMC: 11345452. DOI: 10.1038/s41598-024-70787-8.


References
1.
Kainz H, Modenese L, Lloyd D, Maine S, Walsh H, Carty C . Joint kinematic calculation based on clinical direct kinematic versus inverse kinematic gait models. J Biomech. 2016; 49(9):1658-1669. DOI: 10.1016/j.jbiomech.2016.03.052. View

2.
Peters A, Galna B, Sangeux M, Morris M, Baker R . Quantification of soft tissue artifact in lower limb human motion analysis: a systematic review. Gait Posture. 2009; 31(1):1-8. DOI: 10.1016/j.gaitpost.2009.09.004. View

3.
Benoit D, Ramsey D, Lamontagne M, Xu L, Wretenberg P, Renstrom P . Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. Gait Posture. 2005; 24(2):152-64. DOI: 10.1016/j.gaitpost.2005.04.012. View

4.
Wu G, Siegler S, Allard P, Kirtley C, Leardini A, Rosenbaum D . ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. J Biomech. 2002; 35(4):543-8. DOI: 10.1016/s0021-9290(01)00222-6. View

5.
Ludbrook J . Multiple comparison procedures updated. Clin Exp Pharmacol Physiol. 1999; 25(12):1032-7. DOI: 10.1111/j.1440-1681.1998.tb02179.x. View