Effect of Skin Movement Artifact on Knee Kinematics During Gait and Cutting Motions Measured in Vivo

Overview
Journal Gait Posture
Specialty Orthopedics
Date 2005 Nov 2
PMID 16260140
Citations 101
Authors
Affiliations
Soon will be listed here.
Abstract

Eight healthy male subjects had intra-cortical bone-pins inserted into the proximal tibia and distal femur. Three reflective markers were attached to each bone-pin and four reflective markers were mounted on the skin of the tibia and thigh, respectively. Roentgen-stereophotogrammetric analysis (RSA) was used to determine the anatomical reference frame of the tibia and femur. Knee joint motion was recorded during walking and cutting using infrared cameras sampling at 120Hz. The kinematics derived from the bone-pin markers were compared with that of the skin-markers. Average rotational errors of up to 4.4 degrees and 13.1 degrees and translational errors of up to 13.0 and 16.1mm were noted for the walk and cut, respectively. Although skin-marker derived kinematics could provide repeatable results this was not representative of the motion of the underlying bones. A standard error of measurement is proposed for the reporting of 3D knee joint kinematics.

Citing Articles

Reducing soft tissue artefacts through projection of markers and microwave imaging: An exploratory study.

Radhakrishnan V, Robinson M, Fiorentino N, Patil S, Pelah A Sci Rep. 2025; 15(1):7679.

PMID: 40044738 PMC: 11883034. DOI: 10.1038/s41598-025-89586-w.


Evaluation of drop vertical jump kinematics and kinetics using 3D markerless motion capture in a large cohort.

Templin T, Riehm C, Eliason T, Hulburt T, Kwak S, Medjaouri O Front Bioeng Biotechnol. 2024; 12:1426677.

PMID: 39512656 PMC: 11540714. DOI: 10.3389/fbioe.2024.1426677.


Comparison of IMU-Based Knee Kinematics with and without Harness Fixation against an Optical Marker-Based System.

Weber J, Ortigas-Vasquez A, Sauer A, Dupraz I, Utz M, Maas A Bioengineering (Basel). 2024; 11(10).

PMID: 39451352 PMC: 11505205. DOI: 10.3390/bioengineering11100976.


Computer vision for kinematic metrics of the drinking task in a pilot study of neurotypical participants.

Huber J, Slone S, Bae J Sci Rep. 2024; 14(1):20668.

PMID: 39237646 PMC: 11377576. DOI: 10.1038/s41598-024-71470-8.


Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics.

Auer S, Suss F, Dendorfer S Technol Health Care. 2024; 32(5):3433-3442.

PMID: 38905067 PMC: 11492134. DOI: 10.3233/THC-240202.