Hip joint center (HJC) measurement error can adversely affect predictions from biomechanical models. Soft tissue artifact (STA) may exacerbate HJC errors during dynamic motions. We quantified HJC error and the effect of STA in 11 young, asymptomatic adults during six activities. Subjects were imaged simultaneously with reflective skin markers (SM) and dual fluoroscopy (DF), an x-ray based technique with submillimeter accuracy that does not suffer from STA. Five HJCs were defined from locations of SM using three predictive (i.e., based on regression) and two functional methods; these calculations were repeated using the DF solutions. Hip joint center motion was analyzed during six degrees-of-freedom (default) and three degrees-of-freedom hip joint kinematics. The position of the DF-measured femoral head center (FHC), served as the reference to calculate HJC error. The effect of STA was quantified with mean absolute deviation. HJC errors were (mean±SD) 16.6±8.4mm and 11.7±11.0mm using SM and DF solutions, respectively. HJC errors from SM measurements were all significantly different from the FHC in at least one anatomical direction during multiple activities. The mean absolute deviation of SM-based HJCs was 2.8±0.7mm, which was greater than that for the FHC (0.6±0.1mm), suggesting that STA caused approximately 2.2mm of spurious HJC motion. Constraining the hip joint to three degrees-of-freedom led to approximately 3.1mm of spurious HJC motion. Our results indicate that STA-induced motion of the HJC contributes to the overall error, but inaccuracies inherent with predictive and functional methods appear to be a larger source of error.

Citing Articles

Reducing soft tissue artefacts through projection of markers and microwave imaging: An exploratory study.

Radhakrishnan V, Robinson M, Fiorentino N, Patil S, Pelah A Sci Rep. 2025; 15(1):7679.

PMID: 40044738 PMC: 11883034. DOI: 10.1038/s41598-025-89586-w.


Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion.

Johnson C, Ruh E, Frankston N, Charles S, McClincy M, Anderst W J Biomech Eng. 2024; 146(12).

PMID: 39262043 PMC: 11500802. DOI: 10.1115/1.4066466.


Influence of Skin Marker Positioning and Their Combinations on Hip Joint Center Estimation Using the Functional Method.

Martinez L, Lalevee M, Poirier T, Brunel H, Matsoukis J, Van Driessche S Bioengineering (Basel). 2024; 11(3).

PMID: 38534571 PMC: 10967793. DOI: 10.3390/bioengineering11030297.


Validation of 3D Knee Kinematics during Gait on Treadmill with an Instrumented Knee Brace.

Reneaud N, Zory R, Guerin O, Thomas L, Colson S, Gerus P Sensors (Basel). 2023; 23(4).

PMID: 36850411 PMC: 9968020. DOI: 10.3390/s23041812.


A novel method for measurement of dynamic ischiofemoral space based on MRI and motion capture.

Wang Y, Ma D, Feng Z, Yu W, Chen Y, Zhong S Front Bioeng Biotechnol. 2023; 11:1067600.

PMID: 36761299 PMC: 9905814. DOI: 10.3389/fbioe.2023.1067600.


References
1.
Kapron A, Aoki S, Peters C, Maas S, Bey M, Zauel R . Accuracy and feasibility of dual fluoroscopy and model-based tracking to quantify in vivo hip kinematics during clinical exams. J Appl Biomech. 2014; 30(3):461-70. PMC: 4143504. DOI: 10.1123/jab.2013-0112. View

2.
Bey M, Zauel R, Brock S, Tashman S . Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics. J Biomech Eng. 2006; 128(4):604-9. PMC: 3072582. DOI: 10.1115/1.2206199. View

3.
Harrington M, Zavatsky A, Lawson S, Yuan Z, Theologis T . Prediction of the hip joint centre in adults, children, and patients with cerebral palsy based on magnetic resonance imaging. J Biomech. 2006; 40(3):595-602. DOI: 10.1016/j.jbiomech.2006.02.003. View

4.
Ehrig R, Heller M, Kratzenstein S, Duda G, Trepczynski A, Taylor W . The SCoRE residual: a quality index to assess the accuracy of joint estimations. J Biomech. 2011; 44(7):1400-4. DOI: 10.1016/j.jbiomech.2010.12.009. View

5.
Schwartz M, Rozumalski A . A new method for estimating joint parameters from motion data. J Biomech. 2004; 38(1):107-16. DOI: 10.1016/j.jbiomech.2004.03.009. View