» Articles » PMID: 28296957

Computer Assisted Electromagnetic Navigation Improves Accuracy in Computed Tomography Guided Interventions: A Prospective Randomized Clinical Trial

Overview
Journal PLoS One
Date 2017 Mar 16
PMID 28296957
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To assess the accuracy and usability of an electromagnetic navigation system designed to assist Computed Tomography (CT) guided interventions.

Materials And Methods: 120 patients requiring a percutaneous CT intervention (drainage, biopsy, tumor ablation, infiltration, sympathicolysis) were included in this prospective randomized trial. Nineteen radiologists participated. Conventional procedures (CT group) were compared with procedures assisted by a navigation system prototype using an electromagnetic localizer to track the position and orientation of a needle holder (NAV group). The navigation system displays the needle path in real-time on 2D reconstructed CT images extracted from the 3D CT volume. The regional ethics committee approved this study and all patients gave written informed consent. The main outcome was the distance between the planned trajectory and the achieved needle trajectory calculated from the initial needle placement.

Results: 120 patients were analyzable in intention-to-treat (NAV: 60; CT: 60). Accuracy improved when the navigation system was used: distance error (in millimeters: median[P25%; P75%]) with NAV = 4.1[2.7; 9.1], vs. with CT = 8.9[4.9; 15.1] (p<0.001). After the initial needle placement and first control CT, fewer subsequent CT acquisitions were necessary to reach the target using the navigation system: NAV = 2[2; 3]; CT = 3[2; 4] (p = 0.01).

Conclusion: The tested system was usable in a standard clinical setting and provided significant improvement in accuracy; furthermore, with the help of navigation, targets could be reached with fewer CT control acquisitions.

Citing Articles

The clinical performance of robotic assisted navigation system versus conventional freehand technique for percutaneous transthoracic needle biopsy.

Jing Y, Jing J, Liu J, Zhang J, Jin Y, Bai X Sci Rep. 2025; 15(1):5980.

PMID: 39966451 PMC: 11836355. DOI: 10.1038/s41598-025-87987-5.


Letter to the editor: The use of XperGuide® needle guidance software for CT guided thoracic sympathetic block.

Hammerstein C, Servaas S, Vermeulen E, van Haagen O Interv Pain Med. 2024; 3(4):100439.

PMID: 39351065 PMC: 11439524. DOI: 10.1016/j.inpm.2024.100439.


Cryoprobe Placement Using Electromagnetic Navigation System (IMACTIS® CT-Navigation™) for Cryoablation Treatment of Upper Kidney Pole Lesions and Adrenal Metastases: Experience from a Single-Center, 4-Year Study.

Michailidis A, Kosmoliaptsis P, Dimou G, Mingou G, Zlika S, Giankoulof C Diagnostics (Basel). 2024; 14(17).

PMID: 39272747 PMC: 11393891. DOI: 10.3390/diagnostics14171963.


Evaluation of augmented reality training for a navigation device used for CT-guided needle placement.

Stauffer T, Lohmeyer Q, Melamed S, Uhde A, Hostettler R, Wetzel S Int J Comput Assist Radiol Surg. 2024; 19(12):2411-2419.

PMID: 38717736 PMC: 11607048. DOI: 10.1007/s11548-024-03112-3.


Navigation and Robotics in Interventional Oncology: Current Status and Future Roadmap.

Charalampopoulos G, Bale R, Filippiadis D, Odisio B, Wood B, Solbiati L Diagnostics (Basel). 2024; 14(1).

PMID: 38201407 PMC: 10795729. DOI: 10.3390/diagnostics14010098.


References
1.
Schubert T, Jacob A, Pansini M, Liu D, Gutzeit A, Kos S . CT-guided interventions using a free-hand, optical tracking system: initial clinical experience. Cardiovasc Intervent Radiol. 2012; 36(4):1055-62. DOI: 10.1007/s00270-012-0527-5. View

2.
Wallace M, Chin K, Fletcher T, Bakal C, Cardella J, Grassi C . Quality improvement guidelines for percutaneous drainage/aspiration of abscess and fluid collections. J Vasc Interv Radiol. 2010; 21(4):431-5. DOI: 10.1016/j.jvir.2009.12.398. View

3.
Kim E, Ward T, Patel R, Fischman A, Nowakowski S, Lookstein R . CT-guided liver biopsy with electromagnetic tracking: results from a single-center prospective randomized controlled trial. AJR Am J Roentgenol. 2014; 203(6):W715-23. DOI: 10.2214/AJR.13.12061. View

4.
Moser C, Becker J, Deli M, Busch M, Boehme M, Groenemeyer D . A novel Laser Navigation System reduces radiation exposure and improves accuracy and workflow of CT-guided spinal interventions: a prospective, randomized, controlled, clinical trial in comparison to conventional freehand puncture. Eur J Radiol. 2012; 82(4):627-32. DOI: 10.1016/j.ejrad.2012.10.028. View

5.
Gupta S, Wallace M, Cardella J, Kundu S, Miller D, Rose S . Quality improvement guidelines for percutaneous needle biopsy. J Vasc Interv Radiol. 2010; 21(7):969-75. DOI: 10.1016/j.jvir.2010.01.011. View