» Articles » PMID: 21680125

CT-guided Percutaneous Lung Biopsy: Comparison of Conventional CT Fluoroscopy to CT Fluoroscopy with Electromagnetic Navigation System in 60 Consecutive Patients

Overview
Journal Eur J Radiol
Specialty Radiology
Date 2011 Jun 18
PMID 21680125
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To determine if use of an electromagnetic navigation system (EMN) decreases radiation dose and procedure time of CT fluoroscopy guided lung biopsy in lesions smaller than 2.5 cm.

Materials/methods: 86 consecutive patients with small lung masses (<2.5 cm) were approached. 60 consented and were randomized to undergo biopsy with CT fluoroscopy (CTF) (34 patients) or EMN (26 patients). Technical failure required conversion to CTF in 8/26 EMN patients; 18 patients completed biopsy with EMN. Numerous biopsy parameters were compared as described below.

Results: Average fluoroscopy time using CTF was 28.2s compared to 35.0 s for EMN (p=0.1). Average radiation dose was 117 mGy using CTF and 123 mGy for EMN (p=0.7). Average number of needle repositions was 3.7 for CTF and 4.4 for EMN (p=0.4). Average procedure time was 15 min for CTF and 20 min for EMN (p=0.01). There were 7 pneumothoracesin the CTF group and 6 pneumothoraces in the EMN group (p=0.7). One pneumothorax in the CTF group and 3 pneumothoraces in the EMN group required chest tube placement (p=0.1). One pneumothorax patient in each group required hospital admission. Diagnostic specimens were obtained in 31/34 patients in the CTF group and 22/26 patients in the EMN group (p=0.4).

Conclusions: EMN was not statistically different than CTF for fluoroscopy time, radiation dose, number of needle repositions, incidence of pneumothorax, need for chest tube, or diagnostic yield. Procedure time was increased with EMN.

Citing Articles

The clinical performance of robotic assisted navigation system versus conventional freehand technique for percutaneous transthoracic needle biopsy.

Jing Y, Jing J, Liu J, Zhang J, Jin Y, Bai X Sci Rep. 2025; 15(1):5980.

PMID: 39966451 PMC: 11836355. DOI: 10.1038/s41598-025-87987-5.


Optical navigation robot-assisted puncture system for accurate lung nodule biopsy: an animal study.

Li J, Su L, Liu J, Peng Q, Xu R, Cui W Quant Imaging Med Surg. 2023; 13(12):7789-7801.

PMID: 38106300 PMC: 10722077. DOI: 10.21037/qims-23-576.


Ultrasound Fusion-Guided Core Needle Biopsy for Deep Head and Neck Space Lesions: Technical Feasibility, Histopathologic Yield, and Safety.

Li X, Li J, Zheng N, Hu H, Xie X, Huang G AJNR Am J Neuroradiol. 2023; 44(2):180-185.

PMID: 36702505 PMC: 9891334. DOI: 10.3174/ajnr.A7776.


Comparison of acquisition and iterative reconstruction parameters in abdominal computed tomography-guided procedures: a phantom study.

Frandon J, Akessoul P, Hamard A, Bezandry E, Loffroy R, Addala T Quant Imaging Med Surg. 2022; 12(1):281-291.

PMID: 34993078 PMC: 8666743. DOI: 10.21037/qims-21-328.


Computed Tomography-Navigation™ Electromagnetic System Compared to Conventional Computed Tomography Guidance for Percutaneous Lung Biopsy: A Single-Center Experience.

Lanouziere M, Varbedian O, Chevallier O, Griviau L, Guillen K, Popoff R Diagnostics (Basel). 2021; 11(9).

PMID: 34573873 PMC: 8470612. DOI: 10.3390/diagnostics11091532.