» Articles » PMID: 28065933

Non-contact Hemodynamic Imaging Reveals the Jugular Venous Pulse Waveform

Overview
Journal Sci Rep
Specialty Science
Date 2017 Jan 10
PMID 28065933
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiovascular monitoring is important to prevent diseases from progressing. The jugular venous pulse (JVP) waveform offers important clinical information about cardiac health, but is not routinely examined due to its invasive catheterisation procedure. Here, we demonstrate for the first time that the JVP can be consistently observed in a non-contact manner using a photoplethysmographic imaging system. The observed jugular waveform was strongly negatively correlated to the arterial waveform (r = -0.73 ± 0.17), consistent with ultrasound findings. Pulsatile venous flow was observed over a spatially cohesive region of the neck. Critical inflection points (c, x, v, y waves) of the JVP were observed across all participants. The anatomical locations of the strongest pulsatile venous flow were consistent with major venous pathways identified through ultrasound.

Citing Articles

Exploration of the Conditions for Occurrence of Photoplethysmographic Signal Inversion above the Dorsalis Pedis Artery.

Jerve F, Hjelme D, Kalvoy H, Allen J, Tronstad C Sensors (Basel). 2024; 24(20).

PMID: 39459987 PMC: 11511109. DOI: 10.3390/s24206505.


Artificial Intelligence and Its Role in Diagnosing Heart Failure: A Narrative Review.

Medhi D, Kamidi S, Mamatha Sree K, Shaikh S, Rasheed S, Thengu Murichathil A Cureus. 2024; 16(5):e59661.

PMID: 38836155 PMC: 11148729. DOI: 10.7759/cureus.59661.


Observation of blood motion in the internal jugular vein by contact and contactless photoplethysmography during physiological testing: case studies.

Saiko G, Burton T, Kakihana Y, Hatanaka K, Takahito O, Douplik A Biomed Opt Express. 2024; 15(4):2578-2589.

PMID: 38633071 PMC: 11019709. DOI: 10.1364/BOE.516609.


Capturing the pulse: a state-of-the-art review on camera-based jugular vein assessment.

Arrow C, Ward M, Eshraghian J, Dwivedi G Biomed Opt Express. 2024; 14(12):6470-6492.

PMID: 38420308 PMC: 10898581. DOI: 10.1364/BOE.507418.


Jugular Venous Pulse Waveform Extraction From a Wearable Radio Frequency Sensor.

Conroy T, Zhou J, Kan E IEEE Sens J. 2023; 23(9):10140-10148.

PMID: 38046935 PMC: 10688682. DOI: 10.1109/jsen.2023.3261548.


References
1.
Jacques S . Optical properties of biological tissues: a review. Phys Med Biol. 2013; 58(11):R37-61. DOI: 10.1088/0031-9155/58/11/R37. View

2.
Poh M, McDuff D, Picard R . Advancements in noncontact, multiparameter physiological measurements using a webcam. IEEE Trans Biomed Eng. 2010; 58(1):7-11. DOI: 10.1109/TBME.2010.2086456. View

3.
Xu S, Sun L, Rohde G . Robust efficient estimation of heart rate pulse from video. Biomed Opt Express. 2014; 5(4):1124-35. PMC: 3985994. DOI: 10.1364/BOE.5.001124. View

4.
Kamshilin A, Miridonov S, Teplov V, Saarenheimo R, Nippolainen E . Photoplethysmographic imaging of high spatial resolution. Biomed Opt Express. 2011; 2(4):996-1006. PMC: 3072138. DOI: 10.1364/BOE.2.000996. View

5.
Gibson R, Wood P . The diagnosis of tricuspid stenosis. Br Heart J. 1955; 17(4):552-62. PMC: 503928. DOI: 10.1136/hrt.17.4.552. View