Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse

Overview
Journal Behav Neurol
Publisher Wiley
Specialty Psychiatry
Date 2016 Mar 24
PMID 27006525
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Assessment of cerebral venous return is growing interest for potential application in clinical practice. Doppler ultrasound (DUS) was used as a screening tool. However, three meta-analyses of qualitative DUS protocol demonstrate a big heterogeneity among studies. In an attempt to improve accuracy, several authors alternatively measured the flow rate, based on the product of the time average velocity with the cross-sectional area (CSA). However, also the quantification protocols lacked of the necessary accuracy. The reasons are as follows: (a) automatic measurement of the CSA assimilates the jugular to a circle, while it is elliptical; (b) the use of just a single CSA value in a pulsatile vessel is inaccurate; (c) time average velocity assessment can be applied only in laminar flow. Finally, the tutorial describes alternative ultrasound calculation of flow based on the Womersley method, which takes into account the variation of the jugular CSA overtime. In the near future, it will be possible to synchronize the electrocardiogram with the brain inflow (carotid distension wave) and with the outflow (jugular venous pulse) in order to nicely have a noninvasive ultrasound picture of the brain-heart axis. US jugular venous pulse may have potential use in neurovascular, neurocognitive, neurosensorial, and neurodegenerative disorders.

Citing Articles

Observation of blood motion in the internal jugular vein by contact and contactless photoplethysmography during physiological testing: case studies.

Saiko G, Burton T, Kakihana Y, Hatanaka K, Takahito O, Douplik A Biomed Opt Express. 2024; 15(4):2578-2589.

PMID: 38633071 PMC: 11019709. DOI: 10.1364/BOE.516609.


Non-contact measurement of neck pulses achieved by imaging micro-motions in the neck skin.

He Q, Geng W, Li W, Wang R Biomed Opt Express. 2023; 14(9):4507-4519.

PMID: 37791270 PMC: 10545184. DOI: 10.1364/BOE.501749.


Feasibility of Specular Reflection Imaging for Extraction of Neck Vessel Pressure Waveforms.

Saiko G, Burton T, Douplik A Front Bioeng Biotechnol. 2022; 10:830231.

PMID: 35387295 PMC: 8979108. DOI: 10.3389/fbioe.2022.830231.


Effect of increased positive end-expiratory pressure on intracranial pressure and cerebral oxygenation: impact of respiratory mechanics and hypovolemia.

Chen H, Zhou X, Zhou D, Zhou J, Yu R BMC Neurosci. 2021; 22(1):72.

PMID: 34823465 PMC: 8614026. DOI: 10.1186/s12868-021-00674-9.


Clinical Classification and Collateral Circulation in Chronic Cerebrospinal Venous Insufficiency.

Wang Z, Ding J, Bai C, Ding Y, Ji X, Meng R Front Neurol. 2020; 11:913.

PMID: 33071925 PMC: 7538781. DOI: 10.3389/fneur.2020.00913.


References
1.
Valdueza J, von Munster T, Hoffman O, Schreiber S, Einhaupl K . Postural dependency of the cerebral venous outflow. Lancet. 2000; 355(9199):200-1. DOI: 10.1016/s0140-6736(99)04804-7. View

2.
Doepp F, Schreiber S, Dreier J, Einhaupl K, Valdueza J . Migraine aggravation caused by cephalic venous congestion. Headache. 2003; 43(2):96-8. DOI: 10.1046/j.1526-4610.2003.03024.x. View

3.
Chambers B, Chambers J, Churilov L, Cameron H, Macdonell R . Internal jugular and vertebral vein volume flow in patients with clinically isolated syndrome or mild multiple sclerosis and healthy controls: results from a prospective sonographer-blinded study. Phlebology. 2013; 29(8):528-35. DOI: 10.1177/0268355513505505. View

4.
Sisini F, Tessari M, Menegatti E, Vannini M, Gianesini S, Tavoni V . Clinical Applicability of Assessment of Jugular Flow over the Individual Cardiac Cycle Compared with Current Ultrasound Methodology. Ultrasound Med Biol. 2016; 42(8):1750-63. DOI: 10.1016/j.ultrasmedbio.2016.03.002. View

5.
Kumari U, Heese K . Cardiovascular dementia - a different perspective. Open Biochem J. 2010; 4:29-52. PMC: 2864432. DOI: 10.2174/1874091X01004010029. View