Noncontact Simultaneous Dual Wavelength Photoplethysmography: a Further Step Toward Noncontact Pulse Oximetry

Overview
Journal Rev Sci Instrum
Date 2007 May 5
PMID 17477684
Citations 39
Authors
Affiliations
Soon will be listed here.
Abstract

We present a camera-based device capable of capturing two photoplethysmographic (PPG) signals at two different wavelengths simultaneously, in a remote noncontact manner. The system comprises a complementary metal-oxide semiconductor camera and dual wavelength array of light emitting diodes (760 and 880 nm). By alternately illuminating a region of tissue with each wavelength of light, and detecting the backscattered photons with the camera at a rate of 16 frames/wavelength s, two multiplexed PPG wave forms are simultaneously captured. This process is the basis of pulse oximetry, and we describe how, with the inclusion of a calibration procedure, this system could be used as a noncontact pulse oximeter to measure arterial oxygen saturation (S(p)O(2)) remotely. Results from an experiment on ten subjects, exhibiting normal S(p)O(2) readings, that demonstrate the instrument's ability to capture signals from a range of subjects under realistic lighting and environmental conditions are presented. We compare the signals captured by the noncontact system to a conventional PPG signal captured concurrently from a finger, and show by means of a J. Bland and D. Altman [Lancet 327, 307 (1986); Statistician 32, 307 (1983)] test, the noncontact device to be comparable to a contact device as a monitor of heart rate. We highlight some considerations that should be made when using camera-based "integrative" sampling methods and demonstrate through simulation, the suitability of the captured PPG signals for application of existing pulse oximetry calibration procedures.

Citing Articles

What Remote PPG Oximetry Tells Us about Pulsatile Volume?.

Saiko G Biomedicines. 2024; 12(8).

PMID: 39200248 PMC: 11351970. DOI: 10.3390/biomedicines12081784.


Ninety years of pulse oximetry: history, current status, and outlook.

Quaresima V, Ferrari M, Scholkmann F J Biomed Opt. 2024; 29(Suppl 3):S33307.

PMID: 39156662 PMC: 11330276. DOI: 10.1117/1.JBO.29.S3.S33307.


Deep learning and remote photoplethysmography powered advancements in contactless physiological measurement.

Chen W, Yi Z, Lim L, Lim R, Zhang A, Qian Z Front Bioeng Biotechnol. 2024; 12:1420100.

PMID: 39104628 PMC: 11298756. DOI: 10.3389/fbioe.2024.1420100.


A two-phased study on the use of remote photoplethysmography (rPPG) in paediatric care.

Ahmad Hatib N, Lee J, Chong S, Sng Q, Tan V, Ong G Ann Transl Med. 2024; 12(3):46.

PMID: 38911566 PMC: 11193567. DOI: 10.21037/atm-23-1896.


Spatial averaging method based on adaptive weight for imaging photoplethysmography.

Ryu J, Ryu H, Liang S, Hong S, Lian Y, Zheng Z J Biomed Opt. 2023; 28(8):085003.

PMID: 37655213 PMC: 10466051. DOI: 10.1117/1.JBO.28.8.085003.