Heart failure is associated with a rehospitalisation rate of up to 50% within six months. Elevated central venous pressure may serve as an early warning sign. While invasive procedures are used to measure central venous pressure for guiding treatment in hospital, this becomes impractical upon discharge. A non-invasive estimation technique exists, where the clinician visually inspects the pulsation of the jugular veins in the neck, but it is less reliable due to human limitations. Video and signal processing technologies may offer a high-fidelity alternative. This state-of-the-art review analyses existing literature on camera-based methods for jugular vein assessment. We summarize key design considerations and suggest avenues for future research. Our review highlights the neck as a rich imaging target beyond the jugular veins, capturing comprehensive cardiac signals, and outlines factors affecting signal quality and measurement accuracy. Addressing an often quoted limitation in the field, we also propose minimum reporting standards for future studies.

Citing Articles

Low-cost camera-based assessment of venous hemodynamics in the lower limbs: a study on young healthy volunteers.

Badiola I, Seleng J, Silva D, Blazek V, Leonhardt S, Lueken M Biomed Opt Express. 2025; 16(2):520-534.

PMID: 39958860 PMC: 11828450. DOI: 10.1364/BOE.547794.


Non-Contact Vision-Based Techniques of Vital Sign Monitoring: Systematic Review.

Saikevicius L, Raudonis V, Dervinis G, Baranauskas V Sensors (Basel). 2024; 24(12).

PMID: 38931747 PMC: 11207835. DOI: 10.3390/s24123963.


Introduction to the feature issue: Advances in Optical Biosensors for Biomedical Applications.

Kumar S, Iadicicco A, Kim S, Tosi D, Marques C Biomed Opt Express. 2024; 15(5):3183-3190.

PMID: 38855687 PMC: 11161368. DOI: 10.1364/BOE.527613.

References
1.
Gonzalez S, Hsieh W, Chen T . A benchmark for machine-learning based non-invasive blood pressure estimation using photoplethysmogram. Sci Data. 2023; 10(1):149. PMC: 10030661. DOI: 10.1038/s41597-023-02020-6. View

2.
Nagata R, Harada T, Omote K, Iwano H, Yoshida K, Kato T . Right atrial pressure represents cumulative cardiac burden in heart failure with preserved ejection fraction. ESC Heart Fail. 2022; 9(2):1454-1462. PMC: 8934927. DOI: 10.1002/ehf2.13853. View

3.
Cerina L, Iozzia L, Mainardi L . Influence of acquisition frame-rate and video compression techniques on pulse-rate variability estimation from vPPG signal. Biomed Tech (Berl). 2017; 64(1):53-65. DOI: 10.1515/bmt-2016-0234. View

4.
Taylor C, Ordonez-Mena J, Roalfe A, Lay-Flurrie S, Jones N, Marshall T . Trends in survival after a diagnosis of heart failure in the United Kingdom 2000-2017: population based cohort study. BMJ. 2019; 364:l223. PMC: 6372921. DOI: 10.1136/bmj.l223. View

5.
Khandwalla R, Birkeland K, Zimmer R, Henry T, Nazarian R, Sudan M . Usefulness of Serial Measurements of Inferior Vena Cava Diameter by Vscan to Identify Patients With Heart Failure at High Risk of Hospitalization. Am J Cardiol. 2017; 119(10):1631-1636. DOI: 10.1016/j.amjcard.2017.02.007. View