Abstract

As the key prerequisite of high-speed volumetric structural and functional tissue imaging in real-time, scaling the A-scan rate beyond MHz has been one of the major pursuits in the development of optical coherence tomography (OCT). Along with a handful of techniques enabling multi-MHz, amplified optical time-stretch OCT (AOT-OCT) has recently been demonstrated as a viable alternative for ultrafast swept-source OCT well above MHz without the need for the mechanical wavelength-tuning mechanism. In this paper, we report a new generation of AOT-OCT demonstrating superior performance to its older generation and all other time-stretch-based OCT modalities in terms of shot-to-shot stability, sensitivity (~90dB), roll-off performance (>4 mm/dB) and A-scan rate (11.5 MHz). Such performance is mainly attributed to the combined contribution from the stable operation of the broadband and compact mode-locked fiber laser as well as the optical amplification in-line with the time-stretch process. The system allows us, for the first time, to deliver volumetric time-stretch-based OCT of biological tissues with the single-shot A-scan rate beyond 10 MHz. Comparing with the existing high-speed OCT systems, the inertia-free AOT-OCT shows promises to realize high-performance 3D OCT imaging at video rate.

Citing Articles

Reconstruction of Optical Coherence Tomography Images from Wavelength Space Using Deep Learning.

Viqar M, Sahin E, Stoykova E, Madjarova V Sensors (Basel). 2025; 25(1.

PMID: 39796883 PMC: 11723098. DOI: 10.3390/s25010093.


Microscope integrated MHz optical coherence tomography system for neurosurgery: development and clinical in-vivo imaging.

Draxinger W, Detrez N, Strenge P, Danicke V, Theisen-Kunde D, Schutzeck L Biomed Opt Express. 2024; 15(10):5960-5979.

PMID: 39421776 PMC: 11482179. DOI: 10.1364/BOE.530976.


burn scar assessment with speckle decorrelation and joint spectral and time domain optical coherence tomography.

Wang Q, Gong P, Afsharan H, Joo C, Morellini N, Fear M J Biomed Opt. 2023; 28(12):126001.

PMID: 38074217 PMC: 10704265. DOI: 10.1117/1.JBO.28.12.126001.


Dual-modality imaging system for monitoring human heart organoids beating in vitro.

Hao S, Ren C, Wang F, Park K, Volmert B, Aguirre A Opt Lett. 2023; 48(15):3929-3932.

PMID: 37527085 PMC: 10707703. DOI: 10.1364/OL.493824.


Optical coherence tomography.

Bouma B, de Boer J, Huang D, Jang I, Yonetsu T, Leggett C Nat Rev Methods Primers. 2023; 2.

PMID: 36751306 PMC: 9901537. DOI: 10.1038/s43586-022-00162-2.


References
1.
Wei X, Xu J, Xu Y, Yu L, Xu J, Li B . Breathing laser as an inertia-free swept source for high-quality ultrafast optical bioimaging. Opt Lett. 2014; 39(23):6593-6. DOI: 10.1364/OL.39.006593. View

2.
Tsai T, Potsaid B, Tao Y, Jayaraman V, Jiang J, Heim P . Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology. Biomed Opt Express. 2013; 4(7):1119-32. PMC: 3704093. DOI: 10.1364/BOE.4.001119. View

3.
Oh W, Vakoc B, Shishkov M, Tearney G, Bouma B . >400 kHz repetition rate wavelength-swept laser and application to high-speed optical frequency domain imaging. Opt Lett. 2010; 35(17):2919-21. PMC: 3003227. DOI: 10.1364/OL.35.002919. View

4.
Solli D, Ropers C, Jalali B . Active control of rogue waves for stimulated supercontinuum generation. Phys Rev Lett. 2008; 101(23):233902. DOI: 10.1103/PhysRevLett.101.233902. View

5.
Klein T, Wieser W, Eigenwillig C, Biedermann B, Huber R . Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm Fourier domain mode-locked laser. Opt Express. 2011; 19(4):3044-62. DOI: 10.1364/OE.19.003044. View