CT Angiography of Neonates and Infants: Comparison of Radiation Dose and Image Quality of Target Mode Prospectively ECG-gated 320-MDCT and Ungated Helical 64-MDCT

Overview
Specialties Oncology
Radiology
Date 2015 Jan 24
PMID 25615779
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

OBJECTIVE. The purpose of this study was to evaluate the radiation dose and image quality of target mode prospectively ECG-gated volumetric CT angiography (CTA) performed with a 320-MDCT scanner compared with the radiation dose and image quality of ungated helical CTA performed with a 64-MDCT scanner. MATERIALS AND METHODS. An experience with CTA for cardiovascular indications in neonates and infants 0-6 months old was retrospectively assessed. Radiation doses and quantitative and qualitative image quality scores of 28 CTA examinations performed with a 320-MDCT scanner and volumetric target mode prospective ECG gating plus iterative reconstruction (target mode) were compared with the doses and scores of 28 CTA examinations performed with a 64-MDCT scanner and ungated helical scanning plus filtered back projection reconstruction (ungated mode). All target mode studies were performed during free breathing. Seven ungated CTA examinations (25%) were performed with general endotracheal anesthesia. The findings of 17 preoperative CTA examinations performed in target mode were also compared with surgical reports for evaluation of diagnostic accuracy. RESULTS. All studies performed with target mode technique were diagnostic for the main clinical indication. Effective doses were significantly lower in the target mode group (0.51 ± 0.19 mSv) compared with the ungated mode group (4.8 ± 1.4 mSv) (p < 0.0001). Quantitative analysis revealed no statistically significant difference between the two groups with respect to signal-to-noise ratio (of pulmonary artery and aorta) and contrast-to-noise ratio. Subjective image quality was significantly better with target mode than with ungated mode (p < 0.0001). CONCLUSION. Target mode prospectively ECG-gated volumetric scanning with iterative reconstruction performed with a 320-MDCT scanner has several benefits in cardiovascular imaging of neonates and infants, including low radiation dose, improved image quality, high diagnostic accuracy, and ability to perform free-breathing studies.

Citing Articles

Reducing Sedation for Pediatric Thoracic CT Imaging Using Volumetric Target-mode EKG Gating.

Shah S, Young C, Morrison J, Chmil M, Ruess L, Krishnamurthy R Pediatr Qual Saf. 2024; 10(1):e779.

PMID: 39734911 PMC: 11671082. DOI: 10.1097/pq9.0000000000000779.


Long-Term Coronary Artery Evaluation Using Noncontrast-Enhanced Magnetic Resonance Angiography in Patients with Kawasaki Disease.

Nonaka H, Tahara M, Yoshiura T, Urayama K, Okano M, Morikawa Y Pediatr Cardiol. 2024; .

PMID: 39719460 DOI: 10.1007/s00246-024-03742-z.


Coronary allograft vasculopathy in post-heart transplant patients: pathogenesis and role of cardiac computed tomography in diagnosis-a comprehensive review.

Sharma V, Agarwal S, Grover T, Malhotra A, Kumar H, Gowda D Ann Med Surg (Lond). 2023; 85(7):3531-3537.

PMID: 37427227 PMC: 10328616. DOI: 10.1097/MS9.0000000000000942.


Recommendations for cardiovascular magnetic resonance and computed tomography in congenital heart disease: a consensus paper from the CMR/CCT working group of the Italian Society of Pediatric Cardiology (SICP) and the Italian College of Cardiac....

Secinaro A, Ait-Ali L, Curione D, Clemente A, Gaeta A, Giovagnoni A Radiol Med. 2022; 127(7):788-802.

PMID: 35608758 PMC: 9308607. DOI: 10.1007/s11547-022-01490-9.


Coronary computed tomography angiography in children.

Malone L, Morin C, Browne L Pediatr Radiol. 2021; 52(13):2498-2509.

PMID: 34734316 PMC: 8566193. DOI: 10.1007/s00247-021-05209-2.