» Articles » PMID: 25177990

Coherent Imaging at the Diffraction Limit

Overview
Date 2014 Sep 2
PMID 25177990
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

X-ray ptychography, a scanning coherent diffractive imaging technique, holds promise for imaging with dose-limited resolution and sensitivity. If the foreseen increase of coherent flux by orders of magnitude can be matched by additional technological and analytical advances, ptychography may approach imaging speeds familiar from full-field methods while retaining its inherently quantitative nature and metrological versatility. Beyond promises of high throughput, spectroscopic applications in three dimensions become feasible, as do measurements of sample dynamics through time-resolved imaging or careful characterization of decoherence effects.

Citing Articles

Synchrotron infrared nanospectroscopy in fourth-generation storage rings.

Santos T, Lordano S, Mayer R, Volpe L, Rodrigues G, Meyer B J Synchrotron Radiat. 2024; 31(Pt 3):547-556.

PMID: 38630437 PMC: 11075719. DOI: 10.1107/S1600577524002364.


Kilohertz serial crystallography with the JUNGFRAU detector at a fourth-generation synchrotron source.

Leonarski F, Nan J, Matej Z, Bertrand Q, Furrer A, Gorgisyan I IUCrJ. 2023; 10(Pt 6):729-737.

PMID: 37830774 PMC: 10619449. DOI: 10.1107/S2052252523008618.


High-speed free-run ptychography at the Australian Synchrotron.

Jones M, van Riessen G, Phillips N, Schrank C, Hinsley G, Afshar N J Synchrotron Radiat. 2022; 29(Pt 2):480-487.

PMID: 35254312 PMC: 8900864. DOI: 10.1107/S1600577521012856.


Broadband X-ray ptychography using multi-wavelength algorithm.

Yao Y, Jiang Y, Klug J, Nashed Y, Roehrig C, Preissner C J Synchrotron Radiat. 2021; 28(Pt 1):309-317.

PMID: 33399582 PMC: 7842233. DOI: 10.1107/S1600577520014708.


Hard X-ray ptychography for optics characterization using a partially coherent synchrotron source.

Moxham T, Parsons A, Zhou T, Alianelli L, Wang H, Laundy D J Synchrotron Radiat. 2020; 27(Pt 6):1688-1695.

PMID: 33147195 PMC: 7642961. DOI: 10.1107/S1600577520012151.


References
1.
Beckers M, Senkbeil T, Gorniak T, Reese M, Giewekemeyer K, Gleber S . Chemical contrast in soft x-ray ptychography. Phys Rev Lett. 2011; 107(20):208101. DOI: 10.1103/PhysRevLett.107.208101. View

2.
Schropp A, Hoppe R, Meier V, Patommel J, Seiboth F, Lee H . Full spatial characterization of a nanofocused x-ray free-electron laser beam by ptychographic imaging. Sci Rep. 2013; 3:1633. PMC: 3620670. DOI: 10.1038/srep01633. View

3.
Giewekemeyer K, Thibault P, Kalbfleisch S, Beerlink A, Kewish C, Dierolf M . Quantitative biological imaging by ptychographic x-ray diffraction microscopy. Proc Natl Acad Sci U S A. 2009; 107(2):529-34. PMC: 2795774. DOI: 10.1073/pnas.0905846107. View

4.
Jones M, Peele A, van Riessen G . Application of a complex constraint for biological samples in coherent diffractive imaging. Opt Express. 2014; 21(25):30275-81. DOI: 10.1364/OE.21.030275. View

5.
Guizar-Sicairos M, Fienup J . Measurement of coherent x-ray focused beams by phase retrieval with transverse translation diversity. Opt Express. 2009; 17(4):2670-85. DOI: 10.1364/oe.17.002670. View