Noise Models for Low Counting Rate Coherent Diffraction Imaging
Overview
Ophthalmology
Affiliations
Coherent diffraction imaging (CDI) is a lens-less microscopy method that extracts the complex-valued exit field from intensity measurements alone. It is of particular importance for microscopy imaging with diffraction set-ups where high quality lenses are not available. The inversion scheme allowing the phase retrieval is based on the use of an iterative algorithm. In this work, we address the question of the choice of the iterative process in the case of data corrupted by photon or electron shot noise. Several noise models are presented and further used within two inversion strategies, the ordered subset and the scaled gradient. Based on analytical and numerical analysis together with Monte-Carlo studies, we show that any physical interpretations drawn from a CDI iterative technique require a detailed understanding of the relationship between the noise model and the used inversion method. We observe that iterative algorithms often assume implicitly a noise model. For low counting rates, each noise model behaves differently. Moreover, the used optimization strategy introduces its own artefacts. Based on this analysis, we develop a hybrid strategy which works efficiently in the absence of an informed initial guess. Our work emphasises issues which should be considered carefully when inverting experimental data.
ssc-cdi: A Memory-Efficient, Multi-GPU Package for Ptychography with Extreme Data.
Tonin Y, Peixinho A, Brandao-Junior M, Ferraz P, Miqueles E J Imaging. 2024; 10(11).
PMID: 39590749 PMC: 11595696. DOI: 10.3390/jimaging10110286.
Wavelength-multiplexed multi-mode EUV reflection ptychography based on automatic differentiation.
Shao Y, Weerdenburg S, Seifert J, Urbach H, Mosk A, Coene W Light Sci Appl. 2024; 13(1):196.
PMID: 39160154 PMC: 11333750. DOI: 10.1038/s41377-024-01558-3.
Nave C IUCrJ. 2023; 10(Pt 5):603-609.
PMID: 37668217 PMC: 10478518. DOI: 10.1107/S205225252300698X.
Revealing nano-scale lattice distortions in implanted material with 3D Bragg ptychography.
Li P, Phillips N, Leake S, Allain M, Hofmann F, Chamard V Nat Commun. 2021; 12(1):7059.
PMID: 34862390 PMC: 8642407. DOI: 10.1038/s41467-021-27224-5.
Efficient ptychographic phase retrieval via a matrix-free Levenberg-Marquardt algorithm.
Kandel S, Maddali S, Nashed Y, Hruszkewycz S, Jacobsen C, Allain M Opt Express. 2021; 29(15):23019-23055.
PMID: 34614577 PMC: 8327924. DOI: 10.1364/OE.422768.