On the Lorentzian Versus Gaussian Character of Time-domain Spin-echo Signals from the Brain As Sampled by Means of Gradient-echoes: Implications for Quantitative Transverse Relaxation Studies

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2014 Aug 1
PMID 25078089
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To determine whether Lorentzian or Gaussian intra-voxel frequency distributions are better suited for modeling data acquired with gradient-echo sampling of single spin-echoes for the simultaneous characterization of irreversible and reversible relaxation rates. Clinical studies (e.g., of brain iron deposition) using such acquisition schemes have typically assumed Lorentzian distributions.

Theory And Methods: Theoretical expressions of the time-domain spin-echo signal for intra-voxel Lorentzian and Gaussian distributions were used to fit data from a human brain scanned at both 1.5 Tesla (T) and 3T, resulting in maps of irreversible and reversible relaxation rates for each model. The relative merits of the Lorentzian versus Gaussian model were compared by means of quality of fit considerations.

Results: Lorentzian fits were equivalent to Gaussian fits primarily in regions of the brain where irreversible relaxation dominated. In the multiple brain regions where reversible relaxation effects become prominent, however, Gaussian fits were clearly superior.

Conclusion: The widespread assumption that a Lorentzian distribution is suitable for quantitative transverse relaxation studies of the brain should be reconsidered, particularly at 3T and higher field strengths as reversible relaxation effects become more prominent. Gaussian distributions offer alternate fits of experimental data that should prove quite useful in general. Magn Reson Med 74:51-62, 2015. © 2014 Wiley Periodicals, Inc.

Citing Articles

Information theoretic evaluation of Lorentzian, Gaussian, Voigt, and symmetric alpha-stable models of reversible transverse relaxation in cervical cancer in vivo at 3 T.

Ciris P MAGMA. 2022; 36(1):119-133.

PMID: 35925432 DOI: 10.1007/s10334-022-01035-1.


In vivo irreversible and reversible transverse relaxation rates in human cerebral cortex via line scans at 7 T with 250 micron resolution perpendicular to the cortical surface.

Balasubramanian M, Mulkern R, Polimeni J Magn Reson Imaging. 2022; 90:44-52.

PMID: 35398027 PMC: 9930184. DOI: 10.1016/j.mri.2022.04.001.


In vivo measurements of irreversible and reversible transverse relaxation rates in human basal ganglia at 7 T: making inferences about the microscopic and mesoscopic structure of iron and calcification deposits.

Balasubramanian M, Polimeni J, Mulkern R NMR Biomed. 2019; 32(11):e4140.

PMID: 31322331 PMC: 6817385. DOI: 10.1002/nbm.4140.


Spectroscopic sampling of the left side of long-TE spin echoes: a free lunch?.

Mulkern R, Balasubramanian M MAGMA. 2017; 31(2):321-340.

PMID: 28884314 DOI: 10.1007/s10334-017-0647-7.


Design of spectral-spatial phase prewinding pulses and their use in small-tip fast recovery steady-state imaging.

Williams S, Nielsen J, Fessler J, Noll D Magn Reson Med. 2017; 79(3):1377-1386.

PMID: 28671320 PMC: 5752636. DOI: 10.1002/mrm.26794.


References
1.
Graham J, Paley M, Grunewald R, Hoggard N, Griffiths P . Brain iron deposition in Parkinson's disease imaged using the PRIME magnetic resonance sequence. Brain. 2000; 123 Pt 12:2423-31. DOI: 10.1093/brain/123.12.2423. View

2.
Yablonskiy D, Haacke E . An MRI method for measuring T2 in the presence of static and RF magnetic field inhomogeneities. Magn Reson Med. 1997; 37(6):872-6. DOI: 10.1002/mrm.1910370611. View

3.
Mackay A, Whittall K, Adler J, Li D, Paty D, Graeb D . In vivo visualization of myelin water in brain by magnetic resonance. Magn Reson Med. 1994; 31(6):673-7. DOI: 10.1002/mrm.1910310614. View

4.
Ordidge R, Gorell J, Deniau J, Knight R, Helpern J . Assessment of relative brain iron concentrations using T2-weighted and T2*-weighted MRI at 3 Tesla. Magn Reson Med. 1994; 32(3):335-41. DOI: 10.1002/mrm.1910320309. View

5.
Ma J, Wehrli F . Method for image-based measurement of the reversible and irreversible contribution to the transverse-relaxation rate. J Magn Reson B. 1996; 111(1):61-9. DOI: 10.1006/jmrb.1996.0060. View