» Articles » PMID: 24753438

Sub-second Proton Imaging of 13C Hyperpolarized Contrast Agents in Water

Overview
Specialty Radiology
Date 2014 Apr 23
PMID 24753438
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Indirect proton detection of (13)C hyperpolarized contrast agents potentially enables greater sensitivity. Presented here is a study of sub-second projection imaging of hyperpolarized (13)C contrast agent addressing the obstacle posed by water suppression for indirect detection in vivo. Sodium acetate phantoms were used to develop and test water suppression and sub-second imaging with frequency-selective RF pulses using spectroscopic and imaging indirect proton detection. A 9.8 mm aqueous solution of (13)C PHIP hyperpolarized 2-hydroxyethyl-(13)C-propionate-d2,3,3 (HEP), <P> ~25% was used for demonstration of indirect proton sub-second imaging detection. Balanced 2D FSSFP (fast steady-state free precession) allowed the recording of proton images with a field of view of 64 × 64 mm(2) and spatial resolution 2 × 2 mm(2) with total acquisition time of less than 0.2 s. In thermally polarized sodium 1-(13)C-acetate, (13) C to (1)H polarization transfer efficiency of 45.1% of the theoretically predicted values was observed in imaging detection corresponding to an 11-fold overall sensitivity improvement compared with direct (13)C FSSFP imaging. (13)C to (1)H polarization transfer efficiency of 27% was observed in imaging detection, corresponding to a 3.25-fold sensitivity improvement compared with direct (13)C FSSFP imaging with hyperpolarized HEP. The range of potential applications and limitations of this sub-second and ultra-sensitive imaging approach are discussed.

Citing Articles

Proton-Only Sensing of Hyperpolarized [1,2-C]Pyruvate.

Mandzhieva I, Adelabu I, Chekmenev E, Theis T ACS Sens. 2022; 7(12):3773-3781.

PMID: 36414238 PMC: 10284333. DOI: 10.1021/acssensors.2c01608.


Background-Free Proton NMR Spectroscopy with Radiofrequency Amplification by Stimulated Emission Radiation.

Joalland B, Theis T, Appelt S, Chekmenev E Angew Chem Int Ed Engl. 2021; 60(50):26298-26302.

PMID: 34459080 PMC: 8629966. DOI: 10.1002/anie.202108939.


Synthetic Approaches for N-Labeled Hyperpolarized Heterocyclic Molecular Imaging Agents for N NMR Signal Amplification by Reversible Exchange in Microtesla Magnetic Fields.

Chukanov N, Shchepin R, Joshi S, Kabir M, Salnikov O, Svyatova A Chemistry. 2021; 27(38):9727-9736.

PMID: 33856077 PMC: 8273115. DOI: 10.1002/chem.202100212.


Increasing the sensitivity of hyperpolarized [ N ]urea detection by serial transfer of polarization to spin-coupled protons.

Kreis F, Wright A, Somai V, Katz-Brull R, Brindle K Magn Reson Med. 2020; 84(4):1844-1856.

PMID: 32153046 PMC: 8629126. DOI: 10.1002/mrm.28241.


Hyperpolarizing Concentrated Metronidazole NO Group over Six Chemical Bonds with More than 15 % Polarization and a 20 Minute Lifetime.

Shchepin R, Birchall J, Chukanov N, Kovtunov K, Koptyug I, Theis T Chemistry. 2019; 25(37):8829-8836.

PMID: 30964568 PMC: 6658333. DOI: 10.1002/chem.201901192.


References
1.
Pfeilsticker J, Ollerenshaw J, Norton V, Weitekamp D . A selective 15N-to-(1)H polarization transfer sequence for more sensitive detection of 15N-choline. J Magn Reson. 2010; 205(1):125-9. DOI: 10.1016/j.jmr.2010.04.010. View

2.
Day S, Kettunen M, Gallagher F, Hu D, Lerche M, Wolber J . Detecting tumor response to treatment using hyperpolarized 13C magnetic resonance imaging and spectroscopy. Nat Med. 2007; 13(11):1382-7. DOI: 10.1038/nm1650. View

3.
Norton V, Weitekamp D . Communication: partial polarization transfer for single-scan spectroscopy and imaging. J Chem Phys. 2011; 135(14):141107. DOI: 10.1063/1.3652965. View

4.
Bastiaansen J, Cheng T, Mishkovsky M, Duarte J, Comment A, Gruetter R . In vivo enzymatic activity of acetylCoA synthetase in skeletal muscle revealed by (13)C turnover from hyperpolarized [1-(13)C]acetate to [1-(13)C]acetylcarnitine. Biochim Biophys Acta. 2013; 1830(8):4171-8. DOI: 10.1016/j.bbagen.2013.03.023. View

5.
Scheffler K, Hennig J . Is TrueFISP a gradient-echo or a spin-echo sequence?. Magn Reson Med. 2003; 49(2):395-7. DOI: 10.1002/mrm.10351. View