» Articles » PMID: 24740217

Minimum Information Necessary for Quantitative Real-time PCR Experiments

Overview
Specialty Molecular Biology
Date 2014 Apr 18
PMID 24740217
Citations 42
Authors
Affiliations
Soon will be listed here.
Abstract

The MIQE (minimum information for the publication of quantitative real-time PCR) guidelines were published in 2009 with the twin aims of providing a blueprint for good real-time quantitative polymerase chain reaction (qPCR) assay design and encouraging the comprehensive reporting of qPCR protocols. It had become increasingly clear that variable pre-assay conditions, poor assay design, and incorrect data analysis were leading to the routine publication of data that were often inconsistent, inaccurate, and wrong. The problem was exacerbated by a lack of transparency of reporting, with the details of technical information inadequate for the purpose of assessing the validity of published qPCR data. This had, and continues to have serious implications for basic research, reducing the potential for translating findings into valuable applications and potentially devastating consequences for clinical practice. Today, the rationale underlying the MIQE guidelines has become widely accepted, with more than 2,200 citations by March 2014 and editorials in Nature and related publications acknowledging the enormity of the problem. However, the problem we now face is rather serious: thousands of publications that report suspect data are populating and corrupting the peer-reviewed scientific literature. It will be some time before the many contradictions apparent in every area of the life sciences are corrected.

Citing Articles

Involvement of pentraxin-3 in the development of hypertension but not left ventricular hypertrophy in male spontaneously hypertensive rats.

Mkhize S, Manilall A, Mokotedi L, Gunter S, Michel F Physiol Rep. 2024; 12(20):e70086.

PMID: 39414396 PMC: 11483509. DOI: 10.14814/phy2.70086.


Simultaneous SERS-decoding detection of multiple pathogens in drinking water with home-made portable double-layer filtration and concentration device.

Wu H, Gao Y, Chen Q, Yao L, Yao B, Yang J Mikrochim Acta. 2024; 191(7):429.

PMID: 38942915 DOI: 10.1007/s00604-024-06492-0.


Low-Density TaqMan® Array Cards for the Detection of Pathogens.

Heaney J, Rolfe K, Gleadall N, Greatorex J, Curran M Methods Microbiol. 2024; 42:199-218.

PMID: 38620215 PMC: 7172410. DOI: 10.1016/bs.mim.2015.06.002.


Interferon-induced protein with tetratricopeptide repeats 5 of black fruit bat () displays a broad inhibition of RNA viruses.

Clayton E, Atasoy M, El Naggar R, Franco A, Rohaim M, Munir M Front Immunol. 2024; 15:1284056.

PMID: 38440728 PMC: 10909918. DOI: 10.3389/fimmu.2024.1284056.


Evaluation of candidate reference genes for quantitative real-time PCR normalization in blood from red deer developing antlers.

Broggini C, Abril N, Carranza J, Membrillo A Sci Rep. 2022; 12(1):16264.

PMID: 36171416 PMC: 9519901. DOI: 10.1038/s41598-022-20676-9.