A Wireless-implantable Microsystem for Continuous Blood Glucose Monitoring

Overview
Publisher IEEE
Date 2013 Jul 16
PMID 23853218
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

A remotely powered implantable microsystem for continuous blood glucose monitoring is presented. The microsystem consists of a microfabricated glucose biosensor flip-chip bonded to a transponder chip. The transponder chip is inductively powered by an external reader with a 13.56-MHz carrier. It then measures the output signal of the glucose biosensor and transmits the measured data back to the external reader using load-shift keying (LSK). The microsystem has a volume of 32 mm(3). The procedures for the microfabrication of the glucose sensor and the assembly of the microsystem are described along with the description of the circuit blocks of the transponder chip. The transponder chip has been fabricated with the TSMC 0.18-mum CMOS process and has a total area of 1.3 x 1.3 mm(2). The chip can measure the sensor output current ranging from 1 nA to 1 muA with less than 0.3% nonlinearity error, provided that the amplitude of the received RF signal is higher than 2.6 V; the circuit consumes a total current of about 110 muA.

Citing Articles

CMOS Point-of-Care Diagnostics Technologies: Recent Advances and Future Prospects.

Moeinfard T, Ghafar-Zadeh E, Magierowski S Micromachines (Basel). 2024; 15(11).

PMID: 39597132 PMC: 11596111. DOI: 10.3390/mi15111320.


Biomimetic Exogenous "Tissue Batteries" as Artificial Power Sources for Implantable Bioelectronic Devices Manufacturing.

Yue O, Wang X, Xie L, Bai Z, Zou X, Liu X Adv Sci (Weinh). 2024; 11(11):e2307369.

PMID: 38196276 PMC: 10953594. DOI: 10.1002/advs.202307369.


A Nanotechnology-Based Approach to Biosensor Application in Current Diabetes Management Practices.

Shoaib A, Darraj A, Khan M, Azmi L, Alalwan A, Alamri O Nanomaterials (Basel). 2023; 13(5).

PMID: 36903746 PMC: 10005622. DOI: 10.3390/nano13050867.


Highly Miniaturized, Low-Power CMOS ASIC Chip for Long-Term Continuous Glucose Monitoring.

Gudlavalleti R, Xi X, Legassey A, Chan P, Li J, Burgess D J Diabetes Sci Technol. 2023; 18(5):1179-1184.

PMID: 36772835 PMC: 11418493. DOI: 10.1177/19322968231153419.


Microfabricated passive resonator biochip for sensitive radiofrequency detection and characterization of glucose.

Koirala G, Kim E, Dhakal R, Chuluunbaatar Z, Jo Y, Kim S RSC Adv. 2022; 8(58):33072-33079.

PMID: 35548156 PMC: 9086445. DOI: 10.1039/c8ra04243h.