A Miniaturized Transcutaneous System for Continuous Glucose Monitoring

Overview
Date 2012 Sep 21
PMID 22992979
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Implantable sensors for continuous glucose monitoring hold great potential for optimal diabetes management. This is often undermined by a variety of issues associated with: (1) negative tissue response; (2) poor sensor performance; and (3) lack of device miniaturization needed to reduce implantation trauma. Herein, we report our initial results towards constructing an implantable device that simultaneously address all three aforementioned issues. In terms of device miniaturization, a highly miniaturized CMOS (complementary metal-oxide-semiconductor) potentiostat and signal processing unit was employed (with a combined area of 0.665 mm(2)). The signal processing unit converts the current generated by a transcutaneous, Clark-type amperometric sensor to output frequency in a linear fashion. The Clark-type amperometric sensor employs stratification of five functional layers to attain a well-balanced mass transfer which in turn yields a linear sensor response from 0 to 25 mM of glucose concentration, well beyond the physiologically observed (2 to 22 mM) range. In addition, it is coated with a thick polyvinyl alcohol (PVA) hydrogel with embedded poly(lactic-co-glycolic acid) (PLGA) microspheres intended to provide continuous, localized delivery of dexamethasone to suppress inflammation and fibrosis. In vivo evaluation in rat model has shown that the transcutaneous sensor system reproducibly tracks repeated glycemic events. Clarke's error grid analysis on the as-obtained glycemic data has indicated that all of the measured glucose readings fell in the desired Zones A & B and none fell in the erroneous Zones C, D and E. Such reproducible operation of the transcutaneous sensor system, together with low power (140 μW) consumption and capability for current-to-frequency conversion renders this a versatile platform for continuous glucose monitoring and other biomedical sensing devices.

Citing Articles

Microfluidic-based systems for the management of diabetes.

Zhang S, Staples A Drug Deliv Transl Res. 2024; 14(11):2989-3008.

PMID: 38509342 PMC: 11445324. DOI: 10.1007/s13346-024-01569-y.


Highly Miniaturized, Low-Power CMOS ASIC Chip for Long-Term Continuous Glucose Monitoring.

Gudlavalleti R, Xi X, Legassey A, Chan P, Li J, Burgess D J Diabetes Sci Technol. 2023; 18(5):1179-1184.

PMID: 36772835 PMC: 11418493. DOI: 10.1177/19322968231153419.


Sterilization of Drug-Loaded Composite Coatings for Implantable Glucose Biosensors.

Tipnis N, Kastellorizios M, Legassey A, Papadimitrakopoulos F, Jain F, Burgess D J Diabetes Sci Technol. 2019; 15(3):646-654.

PMID: 31786953 PMC: 8120053. DOI: 10.1177/1932296819890620.


A Novel Needle-Injectable Millimeter scale Wireless Electrochemical Glucose Sensing Platform for Artificial Pancreas Applications.

Mujeeb-U-Rahman M, Nazari M, Sencan M, Antwerp W Sci Rep. 2019; 9(1):17421.

PMID: 31757994 PMC: 6874672. DOI: 10.1038/s41598-019-53680-7.


Effects of a physical and energetic challenge on male California mice (): modulation by reproductive condition.

Zhao M, Garland Jr T, Chappell M, Andrew J, Harris B, Saltzman W J Exp Biol. 2017; 221(Pt 1).

PMID: 29170256 PMC: 5818025. DOI: 10.1242/jeb.168559.


References
1.
Pickup J, Hussain F, Evans N, Rolinski O, Birch D . Fluorescence-based glucose sensors. Biosens Bioelectron. 2005; 20(12):2555-65. DOI: 10.1016/j.bios.2004.10.002. View

2.
McKean B, Gough D . A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors. IEEE Trans Biomed Eng. 1988; 35(7):526-32. DOI: 10.1109/10.4581. View

3.
Bhardwaj U, Sura R, Papadimitrakopoulos F, Burgess D . PLGA/PVA hydrogel composites for long-term inflammation control following s.c. implantation. Int J Pharm. 2009; 384(1-2):78-86. DOI: 10.1016/j.ijpharm.2009.09.046. View

4.
Ahmadi M, Jullien G . A wireless-implantable microsystem for continuous blood glucose monitoring. IEEE Trans Biomed Circuits Syst. 2013; 3(3):169-80. DOI: 10.1109/TBCAS.2009.2016844. View

5.
Choleau C, Klein J, Reach G, Aussedat B, Wilson G, Gifford R . Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method. Biosens Bioelectron. 2002; 17(8):647-54. DOI: 10.1016/s0956-5663(01)00304-9. View