» Articles » PMID: 23381470

Optical Frequency Domain Imaging of Ex Vivo Pulmonary Resection Specimens: Obtaining One to One Image to Histopathology Correlation

Overview
Journal J Vis Exp
Date 2013 Feb 6
PMID 23381470
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Lung cancer is the leading cause of cancer-related deaths. Squamous cell and small cell cancers typically arise in association with the conducting airways, whereas adenocarcinomas are typically more peripheral in location. Lung malignancy detection early in the disease process may be difficult due to several limitations: radiological resolution, bronchoscopic limitations in evaluating tissue underlying the airway mucosa and identifying early pathologic changes, and small sample size and/or incomplete sampling in histology biopsies. High resolution imaging modalities, such as optical frequency domain imaging (OFDI), provide non-destructive, large area 3-dimensional views of tissue microstructure to depths approaching 2 mm in real time (Figure 1). OFDI has been utilized in a variety of applications, including evaluation of coronary artery atherosclerosis and esophageal intestinal metaplasia and dysplasia. Bronchoscopic OCT/OFDI has been demonstrated as a safe in vivo imaging tool for evaluating the pulmonary airways (Animation). OCT has been assessed in pulmonary airways and parenchyma of animal models and in vivo human airway. OCT imaging of normal airway has demonstrated visualization of airway layering and alveolar attachments, and evaluation of dysplastic lesions has been found useful in distinguishing grades of dysplasia in the bronchial mucosa. OFDI imaging of bronchial mucosa has been demonstrated in a short bronchial segment (0.8 cm). Additionally, volumetric OFDI spanning multiple airway generations in swine and human pulmonary airways in vivo has been described. Endobronchial OCT/OFDI is typically performed using thin, flexible catheters, which are compatible with standard bronchoscopic access ports. Additionally, OCT and OFDI needle-based probes have recently been developed, which may be used to image regions of the lung beyond the airway wall or pleural surface. While OCT/OFDI has been utilized and demonstrated as feasible for in vivo pulmonary imaging, no studies with precisely matched one-to-one OFDI:histology have been performed. Therefore, specific imaging criteria for various pulmonary pathologies have yet to be developed. Histopathological counterparts obtained in vivo consist of only small biopsy fragments, which are difficult to correlate with large OFDI datasets. Additionally, they do not provide the comprehensive histology needed for registration with large volume OFDI. As a result, specific imaging features of pulmonary pathology cannot be developed in the in vivo setting. Precisely matched, one-to-one OFDI and histology correlation is vital to accurately evaluate features seen in OFDI against histology as a gold standard in order to derive specific image interpretation criteria for pulmonary neoplasms and other pulmonary pathologies. Once specific imaging criteria have been developed and validated ex vivo with matched one-to-one histology, the criteria may then be applied to in vivo imaging studies. Here, we present a method for precise, one to one correlation between high resolution optical imaging and histology in ex vivo lung resection specimens. Throughout this manuscript, we describe the techniques used to match OFDI images to histology. However, this method is not specific to OFDI and can be used to obtain histology-registered images for any optical imaging technique. We performed airway centered OFDI with a specialized custom built bronchoscopic 2.4 French (0.8 mm diameter) catheter. Tissue samples were marked with tissue dye, visible in both OFDI and histology. Careful orientation procedures were used to precisely correlate imaging and histological sampling locations. The techniques outlined in this manuscript were used to conduct the first demonstration of volumetric OFDI with precise correlation to tissue-based diagnosis for evaluating pulmonary pathology. This straightforward, effective technique may be extended to other tissue types to provide precise imaging to histology correlation needed to determine fine imaging features of both normal and diseased tissues.

Citing Articles

Visualization and Validation of The Microstructures in The Airway Wall in vivo Using Diffractive Optical Coherence Tomography.

Thiboutot J, Yuan W, Park H, Li D, Loube J, Mitzner W Acad Radiol. 2022; 29(11):1623-1630.

PMID: 35282990 PMC: 9463401. DOI: 10.1016/j.acra.2022.01.008.


Optical coherence tomography for identification of malignant pulmonary nodules based on random forest machine learning algorithm.

Ding M, Pan S, Huang J, Yuan C, Zhang Q, Zhu X PLoS One. 2021; 16(12):e0260600.

PMID: 34971557 PMC: 8719667. DOI: 10.1371/journal.pone.0260600.


Polarization-sensitive optical coherence tomography in end-stage lung diseases: an ex vivo pilot study.

Willemse J, Wener R, Feroldi F, Vaselli M, Kwakkel-Van Erp J, van de Graaf E Biomed Opt Express. 2021; 12(11):6796-6813.

PMID: 34858681 PMC: 8606143. DOI: 10.1364/BOE.435870.


Rapid non-destructive volumetric tumor yield assessment in fresh lung core needle biopsies using polarization sensitive optical coherence tomography.

Nandy S, Helland T, Roop B, Raphaely R, Ly A, Lew M Biomed Opt Express. 2021; 12(9):5597-5613.

PMID: 34692203 PMC: 8515979. DOI: 10.1364/BOE.433346.


Distinguishing Tumor from Associated Fibrosis to Increase Diagnostic Biopsy Yield with Polarization-Sensitive Optical Coherence Tomography.

Hariri L, Adams D, Applegate M, Miller A, Roop B, Villiger M Clin Cancer Res. 2019; 25(17):5242-5249.

PMID: 31175092 PMC: 6726561. DOI: 10.1158/1078-0432.CCR-19-0566.


References
1.
Gora M, Karnowski K, Szkulmowski M, Kaluzny B, Huber R, Kowalczyk A . Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range. Opt Express. 2009; 17(17):14880-94. DOI: 10.1364/oe.17.014880. View

2.
Suter M, Vakoc B, Yachimski P, Shishkov M, Lauwers G, Mino-Kenudson M . Comprehensive microscopy of the esophagus in human patients with optical frequency domain imaging. Gastrointest Endosc. 2008; 68(4):745-53. PMC: 2715833. DOI: 10.1016/j.gie.2008.05.014. View

3.
Xie T, Liu G, Kreuter K, Mahon S, Colt H, Mukai D . In vivo three-dimensional imaging of normal tissue and tumors in the rabbit pleural cavity using endoscopic swept source optical coherence tomography with thoracoscopic guidance. J Biomed Opt. 2010; 14(6):064045. PMC: 2809499. DOI: 10.1117/1.3275478. View

4.
Braaf B, Vermeer K, Sicam V, van Zeeburg E, van Meurs J, de Boer J . Phase-stabilized optical frequency domain imaging at 1-µm for the measurement of blood flow in the human choroid. Opt Express. 2011; 19(21):20886-903. DOI: 10.1364/OE.19.020886. View

5.
Suter M, Jillella P, Vakoc B, Halpern E, Mino-Kenudson M, Lauwers G . Image-guided biopsy in the esophagus through comprehensive optical frequency domain imaging and laser marking: a study in living swine. Gastrointest Endosc. 2009; 71(2):346-53. PMC: 2857407. DOI: 10.1016/j.gie.2009.07.007. View