» Articles » PMID: 22065798

Comparison of Linear and Angular Measurements Using Two-dimensional Conventional Methods and Three-dimensional Cone Beam CT Images Reconstructed from a Volumetric Rendering Program in Vivo

Overview
Date 2011 Nov 9
PMID 22065798
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The aim of this study was to compare the linear and angular measurements made on two-dimensional (2D) conventional cephalometric images and three-dimensional (3D) cone beam CT (CBCT) generated cephalograms derived from a 3D volumetric rendering program.

Methods: Pre-treatment cephalometric digital radiographs of 11 patients and their corresponding CBCT images were randomly selected. The digital cephalometric radiographs were traced using Vista Dent OC (GAC International, Inc Bohemia, NY) and by hand. CBCT and Maxilim® (Medicim, Sint-Niklass, Belgium) software were used to generate cephalograms from the CBCT data set that were then linked to the 3D hard-tissue surface representations. In total, 16 cephalometric landmarks were identified and 18 widely used measurements (11 linear and 7 angular) were performed by 2 independent observers. Intraobserver reliability was assessed by calculating intraclass correlation coefficients (ICC), interobserver reliability was assessed with Student t-test and analysis of variance (ANOVA). Mann-Whitney U-tests and Kruskal-Wallis H tests were also used to compare the three methods (P < 0.05).

Results: The results demonstrated no statistically significant difference between interobserver analyses for CBCT-generated cephalograms (P < 0.05), except for Gonion-Menton (Go-Me) and Condylion-Gnathion (Co-Gn). Intraobserver examinations showed low ICCs, which was an indication of poor reproducibility for Go-Me and Sella-Nasion (S-N) in CBCT-generated cephalograms and poor reproducibility for Articulare-Gonion (Ar-Go) in the 2D hand tracing method (P < 0.05). No statistical significance was found for Vista Dent OC measurements (P > 0.05).

Conclusions: Measurements from in vivo CBCT-generated cephalograms from Maxilim® software were found to be similar to conventional images. Thus, owing to higher radiation exposure, CBCT examinations should only be used when the inherent 3D information could improve the outcome of treatment.

Citing Articles

Correlation Between Facial Asymmetry and Maxillary Sinus Size or Volume Using Dental Cone-Beam Computed Tomography Images.

Takeda M, Kujirai K, Takahashi M, Hatanaka R, Koizumi S, Hikita Y Cureus. 2025; 17(3):e80118.

PMID: 40051697 PMC: 11883143. DOI: 10.7759/cureus.80118.


Comparison of conventional two-dimensional and digital three-dimensional imaging in orthodontics : A systematic review and meta-analysis.

Haude A, Lehmann T, Hennig C, Jacobs C J Orofac Orthop. 2025; .

PMID: 39976657 DOI: 10.1007/s00056-024-00574-7.


Use of CBCT in Orthodontics: A Scoping Review.

Polizzi A, Serra S, Leonardi R J Clin Med. 2024; 13(22).

PMID: 39598084 PMC: 11595122. DOI: 10.3390/jcm13226941.


A systematic review and meta-analysis of accuracy between protrusive interocclusal record and horizontal condylar guidance angle recording methods in dentulous patients.

Potdukhe S, Iyer J, Nadgere J J Indian Prosthodont Soc. 2024; 24(1):3-14.

PMID: 38263553 PMC: 10896306. DOI: 10.4103/jips.jips_382_23.


Concordance and reproducibility in the location of reference points for a volumetric craniofacial analysis: Cross-sectional study.

Romero-Tapiero N, Giraldo-Mejia A, Herrera-Rubio A, Aristizabal-Perez J J Dent Res Dent Clin Dent Prospects. 2023; 17(2):87-95.

PMID: 37649819 PMC: 10462468. DOI: 10.34172/joddd.2023.37025.


References
1.
Scarfe W, Farman A, Sukovic P . Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc. 2006; 72(1):75-80. View

2.
Malkoc S, Sari Z, Usumez S, Koyuturk A . The effect of head rotation on cephalometric radiographs. Eur J Orthod. 2005; 27(3):315-21. DOI: 10.1093/ejo/cjh098. View

3.
Greiner M, Greiner A, Hirschfelder U . Variance of landmarks in digital evaluations: comparison between CT-based and conventional digital lateral cephalometric radiographs. J Orofac Orthop. 2007; 68(4):290-8. DOI: 10.1007/s00056-007-0710-5. View

4.
Lopes P, Moreira C, Perrella A, Antunes J, Cavalcanti M . 3-D volume rendering maxillofacial analysis of angular measurements by multislice CT. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008; 105(2):224-30. DOI: 10.1016/j.tripleo.2007.08.036. View

5.
Brown A, Scarfe W, Scheetz J, Silveira A, Farman A . Linear accuracy of cone beam CT derived 3D images. Angle Orthod. 2009; 79(1):150-7. DOI: 10.2319/122407-599.1. View