Abstract

Objective: This study was designed to determine the precision and accuracy of angular measurements using three-dimensional computed tomography (3D-CT) volume rendering by computer systems.

Study Design: The study population consisted of 28 dried skulls that were scanned with a 64-row multislice CT, and 3D-CT images were generated. Angular measurements, (n = 6) based upon conventional craniometric anatomical landmarks (n = 9), were identified independently in 3D-CT images by 2 radiologists, twice each, and were then performed by 3D-CT imaging. Subsequently, physical measurements were made by a third examiner using a Beyond Crysta-C9168 series 900 device.

Results: The results demonstrated no statistically significant difference between interexaminer and intraexaminer analysis. The mean difference between the physical and 3-D-based angular measurements was -1.18% and -0.89%, respectively, for both examiners, demonstrating high accuracy.

Conclusion: Maxillofacial analysis of angular measurements using 3D-CT volume rendering by 64-row multislice CT is established and can be used for orthodontic and dentofacial orthopedic applications.

Citing Articles

Cross Sectional Analysis of Eurasian Skull Anatomy for 3D Cephalometry-Normative Data Reveal Four Different Skull Types.

Ludwigs L, Pape C, Visse H, Runte C, Meyer U, Dirksen D J Pers Med. 2023; 13(6).

PMID: 37374007 PMC: 10300808. DOI: 10.3390/jpm13061018.


3D cephalometric analysis using Magnetic Resonance Imaging: validation of accuracy and reproducibility.

Juerchott A, Saleem M, Hilgenfeld T, Freudlsperger C, Zingler S, Lux C Sci Rep. 2018; 8(1):13029.

PMID: 30158656 PMC: 6115428. DOI: 10.1038/s41598-018-31384-8.


Hard- and soft-tissue profiles of the midface region in patients with skeletal Class III malocclusion using cone-beam computed tomography multiplanar-reconstructed image analysis.

Kim B, Lee H, Kim S, Kim Y, Son W, Kim S Korean J Orthod. 2018; 48(3):143-152.

PMID: 29732300 PMC: 5932316. DOI: 10.4041/kjod.2018.48.3.143.


Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study.

Liu L, Xu X, Li X, Wu W, Cai J, Lu Q Med Sci Monit. 2017; 23:2871-2878.

PMID: 28604652 PMC: 5478299. DOI: 10.12659/msm.902261.


Accuracy and reliability of cetacean cranial measurements using computed tomography three dimensional volume rendered images.

Yuen A, Tsui H, Kot B PLoS One. 2017; 12(3):e0174215.

PMID: 28329016 PMC: 5362215. DOI: 10.1371/journal.pone.0174215.