» Articles » PMID: 16633181

A New Method of 3-D Cephalometry Part I: the Anatomic Cartesian 3-D Reference System

Overview
Date 2006 Apr 25
PMID 16633181
Citations 58
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study was to present a new innovative three-dimensional (3-D) cephalometric method. Part I deals with the set-up and validation of a voxel-based semi-automatic 3-D cephalometric reference system. The CT data (DICOM 3.0 files) of 20 control patients with normal skeletal relationships were used for this study. To investigate accuracy and reliability of the 3-D cephalometric reference system (Maxilimtrade mark, version 1.3.0) a total of 42 (14 horizontal, 14 vertical and 14 transversal) orthogonal measurements were performed on each patient twice by each of two investigators. The intra-observer measurement error was less then 0.88 mm, 0.76 mm and 0.84 mm for horizontal, vertical and transversal orthogonal measurements, respectively. The inter-observer measurement error was less as 0.78 mm, 0.86 mm and 1.26 mm for horizontal, vertical and transversal orthogonal measurements, respectively. Squared correlation coefficients showed a high intra-observer and inter-observer reliability. The presented 3-D cephalometric reference system proved to be accurate and reliable and can therefore be used for 3-D cephalometric hard and soft tissue analysis.

Citing Articles

Evaluating Surgical Accuracy in Bimaxillary Surgery: A Systematic Review and Meta-Analysis of Mandible-First versus Maxilla-First Approaches.

Yan S, Wu Y, Qiao C, Yan K, Xie Z, Qu Y Aesthetic Plast Surg. 2024; .

PMID: 39394541 DOI: 10.1007/s00266-024-04438-8.


Facial asymmetry outcome of orthognathic surgery in mild craniofacial microsomia compared to non-syndromic class II asymmetry.

Chen Y, Baan F, Berge S, Liao Y, Maal T, Xi T Clin Oral Investig. 2024; 28(9):502.

PMID: 39196436 PMC: 11358178. DOI: 10.1007/s00784-024-05899-6.


The Accuracy of Three-Dimensional Soft Tissue Simulation in Orthognathic Surgery-A Systematic Review.

Olejnik A, Verstraete L, Croonenborghs T, Politis C, Swennen G J Imaging. 2024; 10(5).

PMID: 38786573 PMC: 11122049. DOI: 10.3390/jimaging10050119.


Relationship between Bilateral Landmarks of Facial Asymmetry in Skeletal Class II and Class III in Vertical Dimension: 3D Facial Scan and Cone-Beam Computed Tomography.

Jearanai T, Samruajbenjakun B, Chanmanee P Diagnostics (Basel). 2024; 14(6).

PMID: 38535010 PMC: 10969295. DOI: 10.3390/diagnostics14060590.


Soft tissue compensation evaluation in patients with facial asymmetry using cone-beam computed tomography combined with 3D facial photographs.

Supmaneenukul Y, Khemla C, Parakonthun K Heliyon. 2024; 10(6):e27720.

PMID: 38496872 PMC: 10944279. DOI: 10.1016/j.heliyon.2024.e27720.