Hybrid Use of Early and Quasi-continuous Wave Photons in Time-domain Tomographic Imaging for Improved Resolution and Quantitative Accuracy

Overview
Specialty Radiology
Date 2011 Mar 18
PMID 21412471
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Measurement of early-photons (EPs) from a pulsed laser source has been shown to improve imaging resolution versus continuous wave (CW) systems in diffuse optical tomography (DOT) and fluorescence mediated tomography (FMT). However, EP systems also have reduced noise performance versus CW systems since EP measurements require temporal rejection of large numbers of transmitted photons. In this work, we describe a 'hybrid data set' (HDS) image reconstruction approach, the goal of which was to produce a final image that retained the resolution and noise advantages of EP and CW data sets, respectively. Here, CW data was first reconstructed to produce a quantitatively accurate 'initial guess' intermediate image, and then this was refined with EP data to yield a higher resolution final image. We performed a series of studies with simulated data to test the resolution, quantitative accuracy and detection sensitivity of the approach. We showed that in principle it was possible to produce final images that retained the bulk of the resolution and quantitative accuracy of EP and CW images, respectively, but the HDS approach did not improve the instrument sensitivity compared to EP data alone.

Citing Articles

Hyperspectral wide-field time domain single-pixel diffuse optical tomography platform.

Pian Q, Yao R, Intes X Biomed Opt Express. 2019; 9(12):6258-6272.

PMID: 31065427 PMC: 6491017. DOI: 10.1364/BOE.9.006258.


Multiplexed fluorescence tomography with spectral and temporal data: demixing with intrinsic regularization.

Pera V, Brooks D, Niedre M Biomed Opt Express. 2016; 7(1):111-31.

PMID: 26819822 PMC: 4722896. DOI: 10.1364/BOE.7.000111.


Fast single photon avalanche photodiode-based time-resolved diffuse optical tomography scanner.

Mu Y, Niedre M Biomed Opt Express. 2015; 6(9):3596-609.

PMID: 26417526 PMC: 4574682. DOI: 10.1364/BOE.6.003596.


Instrumentation in Diffuse Optical Imaging.

Zhang X Photonics. 2014; 1(1):9-32.

PMID: 24860804 PMC: 4031606. DOI: 10.3390/photonics1010009.


Resolution below the point spread function for diffuse optical imaging using fluorescence lifetime multiplexing.

Rice W, Hou S, Kumar A Opt Lett. 2013; 38(12):2038-40.

PMID: 23938969 PMC: 3992832. DOI: 10.1364/OL.38.002038.


References
1.
Graves E, Ripoll J, Weissleder R, Ntziachristos V . A submillimeter resolution fluorescence molecular imaging system for small animal imaging. Med Phys. 2003; 30(5):901-11. DOI: 10.1118/1.1568977. View

2.
Turner G, Soubret A, Ntziachristos V . Inversion with early photons. Med Phys. 2007; 34(4):1405-11. DOI: 10.1118/1.2437103. View

3.
Valim N, Brock J, Niedre M . Experimental measurement of time-dependent photon scatter for diffuse optical tomography. J Biomed Opt. 2011; 15(6):065006. PMC: 3014223. DOI: 10.1117/1.3523371. View

4.
Piao D, Xie H, Zhang W, Krasinski J, Zhang G, Dehghani H . Endoscopic, rapid near-infrared optical tomography. Opt Lett. 2006; 31(19):2876-8. DOI: 10.1364/ol.31.002876. View

5.
Kumar A, Raymond S, Bacskai B, Boas D . Comparison of frequency-domain and time-domain fluorescence lifetime tomography. Opt Lett. 2008; 33(5):470-2. PMC: 2913597. DOI: 10.1364/ol.33.000470. View