Three-dimensional Diffuse Optical Tomography in the Parallel Plane Transmission Geometry: Evaluation of a Hybrid Frequency Domain/continuous Wave Clinical System for Breast Imaging

Overview
Journal Med Phys
Specialty Biophysics
Date 2003 Feb 28
PMID 12607841
Citations 77
Authors
Affiliations
Soon will be listed here.
Abstract

Three-dimensional diffuse optical tomography (DOT) of breast requires large data sets for even modest resolution (1 cm). We present a hybrid DOT system that combines a limited number of frequency domain (FD) measurements with a large set of continuous wave (cw) measurements. The FD measurements are used to quantitatively determine tissue averaged absorption and scattering coefficients. The larger cw data sets (10(5) measurements) collected with a lens coupled CCD, permit 3D DOT reconstructions of a 1-liter tissue volume. To address the computational complexity of large data sets and 3D volumes we employ finite difference based reconstructions computed in parallel. Tissue phantom measurements evaluate imaging performance. The tests include the following: point spread function measures of resolution, characterization of the size and contrast of single objects, field of view measurements and spectral characterization of constituent concentrations. We also report in vivo measurements. Average tissue optical properties of a healthy breast are used to deduce oxy- and deoxy-hemoglobin concentrations. Differential imaging with a tumor simulating target adhered to the surface of a healthy breast evaluates the influence of physiologic fluctuations on image noise. This tomography system provides robust, quantitative, full 3D image reconstructions with the advantages of high data throughput, single detector-tissue coupling path, and large (1L) imaging domains. In addition, we find that point spread function measurements provide a useful and comprehensive representation of system performance.

Citing Articles

Rapid diffused optical imaging for accurate 3D estimation of subcutaneous tissue features.

Cai S, Mai J, Hong W, Fraser S, Cutrale F iScience. 2025; 28(2):111818.

PMID: 39991548 PMC: 11847144. DOI: 10.1016/j.isci.2025.111818.


An affordable, wearable, fiber-free pulsed-mode diffuse speckle contrast flowmetry (PM-DSCF) sensor for noninvasive measurements of deep cerebral blood flow.

Yeo C, Liu X, Mohtasebi M, Akbari F, Fathi F, Yu G ArXiv. 2025; .

PMID: 39990801 PMC: 11844631.


Revisiting the Rytov approximation in diffuse optics and its applications for the inverse and forward problems.

Sassaroli A, Blaney G, Martelli F, Fantini S Sci Rep. 2024; 14(1):31266.

PMID: 39732813 PMC: 11682099. DOI: 10.1038/s41598-024-82682-3.


Frequency-domain instrument with custom ASIC for dual-slope near-infrared spectroscopy.

Kilic A, Blaney G, Tavakoli F, Frias J, Sassaroli A, Fantini S Rev Sci Instrum. 2024; 95(11).

PMID: 39527001 PMC: 11585364. DOI: 10.1063/5.0227363.


Fundamental effects of array density and modulation frequency on image quality of diffuse optical tomography.

Fan W, Trobaugh J, Zhang C, Yang D, Culver J, Eggebrecht A Med Phys. 2024; 52(2):1045-1057.

PMID: 39494917 PMC: 11788260. DOI: 10.1002/mp.17491.