MR Water Quantitative Priors Improves the Accuracy of Optical Breast Imaging

Overview
Date 2010 Sep 4
PMID 20813635
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Magnetic resonance (MR) guided optical breast imaging is a promising modality to improve the specificity of breast imaging, because it provides high-resolution quantitative maps of total hemoglobin, oxygen saturation, water content, and optical scattering. These properties have been shown to distinguish malignant from benign lesions. However, the optical detection hardware required for deep tissue imaging has poor spectral sensitivity which limits accurate water quantification; this reduces the accuracy of hemoglobin quantification. We present a methodology to improve optical quantification by utilizing the ability of Dixon MR imaging to quantitatively estimate water and fat; this technique effectively reduces optical crosstalk between water and oxyhemoglobin. The techniques described in this paper reduce hemoglobin quantification error by as much as 38%, as shown in a numerical phantom, and an experimental phantom. Error is reduced by as much 20% when imperfect MR water quantification is given. These techniques may also increase contrast between diseased and normal tissue, as shown in breast tissue in vivo. It is also shown that using these techniques may permit fewer wavelengths to be used with similar quantitative accuracy, enabling higher temporal resolution. In addition, it is shown that these techniques can improve the ability of MRI to quantify water in the presence of bias in the Dixon water/fat separation.

Citing Articles

Systematic study of the effect of ultrasound gel on the performances of time-domain diffuse optics and diffuse correlation spectroscopy.

Di Sieno L, Contini D, Lo Presti G, Cortese L, Mateo T, Rosinski B Biomed Opt Express. 2019; 10(8):3899-3915.

PMID: 31452983 PMC: 6701515. DOI: 10.1364/BOE.10.003899.


Collagen Complexity Spatially Defines Microregions of Total Tissue Pressure in Pancreatic Cancer.

Nieskoski M, Marra K, Gunn J, Hoopes P, Doyley M, Hasan T Sci Rep. 2017; 7(1):10093.

PMID: 28855644 PMC: 5577321. DOI: 10.1038/s41598-017-10671-w.


Sensitivity of MRI-guided near-infrared spectroscopy clinical breast exam data and its impact on diagnostic performance.

Mastanduno M, Xu J, El-Ghussein F, Jiang S, Yin H, Zhao Y Biomed Opt Express. 2014; 5(9):3103-15.

PMID: 25401024 PMC: 4230863. DOI: 10.1364/BOE.5.003103.


Implicit and explicit prior information in near-infrared spectral imaging: accuracy, quantification and diagnostic value.

Pogue B, Davis S, Leblond F, Mastanduno M, Dehghani H, Paulsen K Philos Trans A Math Phys Eng Sci. 2011; 369(1955):4531-57.

PMID: 22006905 PMC: 3263784. DOI: 10.1098/rsta.2011.0228.

References
1.
Yalavarthy P, Pogue B, Dehghani H, Carpenter C, Jiang S, Paulsen K . Structural information within regularization matrices improves near infrared diffuse optical tomography. Opt Express. 2009; 15(13):8043-58. DOI: 10.1364/oe.15.008043. View

2.
Brooksby B, Jiang S, Dehghani H, Pogue B, Paulsen K, Weaver J . Combining near-infrared tomography and magnetic resonance imaging to study in vivo breast tissue: implementation of a Laplacian-type regularization to incorporate magnetic resonance structure. J Biomed Opt. 2005; 10(5):051504. DOI: 10.1117/1.2098627. View

3.
Durduran T, Choe R, Culver J, Zubkov L, Holboke M, Giammarco J . Bulk optical properties of healthy female breast tissue. Phys Med Biol. 2002; 47(16):2847-61. DOI: 10.1088/0031-9155/47/16/302. View

4.
Grosenick D, Wabnitz H, Moesta K, Mucke J, Moller M, Stroszczynski C . Concentration and oxygen saturation of haemoglobin of 50 breast tumours determined by time-domain optical mammography. Phys Med Biol. 2004; 49(7):1165-81. DOI: 10.1088/0031-9155/49/7/006. View

5.
Corlu A, Durduran T, Choe R, Schweiger M, Hillman E, Arridge S . Uniqueness and wavelength optimization in continuous-wave multispectral diffuse optical tomography. Opt Lett. 2003; 28(23):2339-41. DOI: 10.1364/ol.28.002339. View