» Articles » PMID: 14640767

Comparison of Water and Lipid Content Measurements Using Diffuse Optical Spectroscopy and MRI in Emulsion Phantoms

Overview
Date 2003 Dec 4
PMID 14640767
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

We present a quantitative comparison of lipid and water signals obtained from broadband Diffuse Optical Spectroscopy (DOS) and Magnetic Resonance Imaging (MRI). DOS and MRI measurements were performed on an identical set of emulsion phantoms that were composed of different water/soybean oil fractions. Absolute concentrations of water and lipid ranging from 35-94% and 63-6%, respectively were calculated from quantitative broadband near-infrared (NIR) absorption spectra (650-1000 nm). MR images of fat and water were separated using the three-point Dixon technique. DOS and MRI measured water and lipid were highly correlated (R(2) = 0.98 and R(2) = 0.99, respectively) suggesting that these techniques are complementary over a broad range of physiologically relevant water and lipid values. In addition, comparison of DOS derived concentrations to the MRI "gold standard" technique validates our quantitation approach and permits estimation of DOS accuracy and sensitivity in vivo.

Citing Articles

Understanding ADC variation by fat content effect using a dual-function MRI phantom.

Liu Y, Tsai T, Li Y, Peng J, Chang H, Peng H Eur Radiol Exp. 2024; 8(1):19.

PMID: 38347188 PMC: 10861416. DOI: 10.1186/s41747-023-00414-0.


Spectral correction of light emitting diodes enables accurate hydration ratio calculation using narrowband diffuse reflectance spectroscopy.

Lam J, Kim J, Tu K, Kim D, Kim S J Biomed Opt. 2023; 28(7):075005.

PMID: 37529204 PMC: 10387445. DOI: 10.1117/1.JBO.28.7.075005.


Shortwave infrared diffuse optical wearable probe for quantification of water and lipid content in emulsion phantoms using deep learning.

Spink S, Pilvar A, Wei L, Frias J, Anders K, Franco S J Biomed Opt. 2023; 28(9):094808.

PMID: 37313427 PMC: 10258729. DOI: 10.1117/1.JBO.28.9.094808.


VIS-NIR Diffuse Reflectance Spectroscopy System with Self-Calibrating Fiber-Optic Probe: Study of Perturbation Resistance.

Perekatova V, Kostyuk A, Kirillin M, Sergeeva E, Kurakina D, Shemagina O Diagnostics (Basel). 2023; 13(3).

PMID: 36766562 PMC: 9913927. DOI: 10.3390/diagnostics13030457.


Rapid Characterization of Solid Tumors Using Resonant Sensors.

Beierle A, Quinn C, Markert H, Carr A, Marayati R, Bownes L ACS Omega. 2022; 7(36):32690-32700.

PMID: 36119978 PMC: 9476530. DOI: 10.1021/acsomega.2c04345.