» Articles » PMID: 20152026

Semi-automatic Quantification of 4D Left Ventricular Blood Flow

Overview
Publisher Elsevier
Date 2010 Feb 16
PMID 20152026
Citations 85
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The beating heart is the generator of blood flow through the cardiovascular system. Within the heart's own chambers, normal complex blood flow patterns can be disturbed by diseases. Methods for the quantification of intra-cardiac blood flow, with its 4D (3D+time) nature, are lacking. We sought to develop and validate a novel semi-automatic analysis approach that integrates flow and morphological data.

Method: In six healthy subjects and three patients with dilated cardiomyopathy, three-directional, three-dimensional cine phase-contrast cardiovascular magnetic resonance (CMR) velocity data and balanced steady-state free-precession long- and short-axis images were acquired. The LV endocardium was segmented from the short-axis images at the times of isovolumetric contraction (IVC) and isovolumetric relaxation (IVR). At the time of IVC, pathlines were emitted from the IVC LV blood volume and traced forwards and backwards in time until IVR, thus including the entire cardiac cycle. The IVR volume was used to determine if and where the pathlines left the LV. This information was used to automatically separate the pathlines into four different components of flow: Direct Flow, Retained Inflow, Delayed Ejection Flow and Residual Volume. Blood volumes were calculated for every component by multiplying the number of pathlines with the blood volume represented by each pathline. The accuracy and inter- and intra-observer reproducibility of the approach were evaluated by analyzing volumes of LV inflow and outflow, the four flow components, and the end-diastolic volume.

Results: The volume and distribution of the LV flow components were determined in all subjects. The calculated LV outflow volumes [ml] (67 +/- 13) appeared to fall in between those obtained by through-plane phase-contrast CMR (77 +/- 16) and Doppler ultrasound (58 +/- 10), respectively. Calculated volumes of LV inflow (68 +/- 11) and outflow (67 +/- 13) were well matched (NS). Low inter- and intra-observer variability for the assessment of the volumes of the flow components was obtained.

Conclusions: This semi-automatic analysis approach for the quantification of 4D blood flow resulted in accurate LV inflow and outflow volumes and a high reproducibility for the assessment of LV flow components.

Citing Articles

The effect of respiratory motion compensation in intracardiac 4D flow magnetic resonance imaging on left ventricular flow dynamics, multicomponent particle tracing, and valve tracking.

Roos P, In de Braekt T, Lamb H, Westenberg J Eur Heart J Imaging Methods Pract. 2025; 3(1):qyaf020.

PMID: 40066147 PMC: 11891475. DOI: 10.1093/ehjimp/qyaf020.


Understanding Right Heart Flow: Implications for Interatrial Shunt Device Therapy in Heart Failure.

Guddeti R, Garg P, Kereiakes D, Cavalcante J, Carlsson M, Garcia S J Soc Cardiovasc Angiogr Interv. 2025; 4(1):102439.

PMID: 40061421 PMC: 11887558. DOI: 10.1016/j.jscai.2024.102439.


Right Ventricular Dysfunction in Cardiac Anesthesia: Perioperative Assessment and Underlying Mechanisms.

Hori K, Watanabe R, Tsujikawa S, Hino H, Matsuura T, Mori T Rev Cardiovasc Med. 2025; 26(2):26286.

PMID: 40026500 PMC: 11868895. DOI: 10.31083/RCM26286.


Characterization of Intracardiac Flow in the Right Ventricle With Pressure and Volume Overload in Children.

Hayabuchi Y, Homma Y Cardiol Res. 2025; 16(1):22-32.

PMID: 39897445 PMC: 11779675. DOI: 10.14740/cr2009.


Intracardiac fluid dynamic analysis: available techniques and novel clinical applications.

Leo I, Cersosimo A, Ielapi J, Sabatino J, Sicilia F, Strangio A BMC Cardiovasc Disord. 2024; 24(1):716.

PMID: 39702022 PMC: 11660877. DOI: 10.1186/s12872-024-04371-3.


References
1.
Napel S, Lee D, Frayne R, Rutt B . Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging. J Magn Reson Imaging. 1992; 2(2):143-53. DOI: 10.1002/jmri.1880020206. View

2.
Markl M, Draney M, Hope M, Levin J, Chan F, Alley M . Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients. J Comput Assist Tomogr. 2004; 28(4):459-68. DOI: 10.1097/00004728-200407000-00005. View

3.
Kilner P, Yang G, Wilkes A, Mohiaddin R, Firmin D, Yacoub M . Asymmetric redirection of flow through the heart. Nature. 2000; 404(6779):759-61. DOI: 10.1038/35008075. View

4.
Takano H, Hasegawa H, Nagai T, Komuro I . Implication of cardiac remodeling in heart failure: mechanisms and therapeutic strategies. Intern Med. 2003; 42(6):465-9. DOI: 10.2169/internalmedicine.42.465. View

5.