» Articles » PMID: 8669711

Three-dimensional Reconstruction of the Flow in a Human Left Heart by Using Magnetic Resonance Phase Velocity Encoding

Overview
Journal Ann Biomed Eng
Date 1996 Jan 1
PMID 8669711
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Intraventricular flows have been correlated with disease and are of interest to cardiologists as a possible means of diagnosis. This study extends a method that use magnetic resonance (MR) to measure the three-dimensional nature of these flows. Four coplanar, sagittal MR slices were located that spanned the left ventricle of a healthy human. All three velocity components were measured in each slice and 18 phases were obtained per beat. With use of the MR magnitude images, masks were created to isolate the velocity data within the heart. These data were read into the software package, Data Visualizer, and the data from the four slices were aligned so as to reconstruct the three-dimensional volume of the left ventricle and atrium. By representing the velocity in vectorial form, the three-dimensional intraventricular flow field was visualized. This revealed the presence of one large line vortex in the ventricle during late diastole but a more ordered flow during early diastole and systole. In conclusion, the use of MR velocity acquisition is a suitable method to obtain the complex intraventricular flow fields in humans and may lead to a better understanding of the importance of these flows.

Citing Articles

CT-Based Simulation of Left Ventricular Hemodynamics: A Pilot Study in Mitral Regurgitation and Left Ventricle Aneurysm Patients.

Obermeier L, Vellguth K, Schlief A, Tautz L, Bruening J, Knosalla C Front Cardiovasc Med. 2022; 9:828556.

PMID: 35391837 PMC: 8980692. DOI: 10.3389/fcvm.2022.828556.


Semi-automatic quantification of 4D left ventricular blood flow.

Eriksson J, Carlhall C, Dyverfeldt P, Engvall J, Bolger A, Ebbers T J Cardiovasc Magn Reson. 2010; 12:9.

PMID: 20152026 PMC: 2831022. DOI: 10.1186/1532-429X-12-9.


Three dimensional flow in the human left atrium.

Fyrenius A, Wigstrom L, Ebbers T, Karlsson M, Engvall J, Bolger A Heart. 2001; 86(4):448-55.

PMID: 11559688 PMC: 1729920. DOI: 10.1136/heart.86.4.448.

References
1.
Delemarre B, Bot H, Visser C, Dunning A . Pulsed Doppler echocardiographic description of a circular flow pattern in spontaneous left ventricular contrast. J Am Soc Echocardiogr. 1988; 1(2):114-8. DOI: 10.1016/s0894-7317(88)80092-0. View

2.
Yoganathan A, Lemmon Jr J, Kim Y, Walker P, Levine R, Vesier C . A computational study of a thin-walled three-dimensional left ventricle during early systole. J Biomech Eng. 1994; 116(3):307-14. DOI: 10.1115/1.2895735. View

3.
Matsuda T, Shimizu K, Sakurai T, Fujita A, Ohara H, Okamura S . Measurement of aortic blood flow with MR imaging: comparative study with Doppler US. Radiology. 1987; 162(3):857-61. DOI: 10.1148/radiology.162.3.3544040. View

4.
Sun Y, Hearshen D, Rankin G, Haggar A . Comparison of velocity-encoded MR imaging and fluid dynamic modeling of steady and disturbed flow. J Magn Reson Imaging. 1992; 2(4):443-52. DOI: 10.1002/jmri.1880020414. View

5.
Jacobs L, Kotler M, Parry W . Flow patterns in dilated cardiomyopathy: a pulsed-wave and color flow Doppler study. J Am Soc Echocardiogr. 1990; 3(4):294-302. DOI: 10.1016/s0894-7317(14)80312-x. View