» Articles » PMID: 38211658

Deep Learning Based Automated Left Ventricle Segmentation and Flow Quantification in 4D Flow Cardiac MRI

Overview
Publisher Elsevier
Date 2024 Jan 11
PMID 38211658
Authors
Affiliations
Soon will be listed here.
Abstract

Background: 4D flow MRI enables assessment of cardiac function and intra-cardiac blood flow dynamics from a single acquisition. However, due to the poor contrast between the chambers and surrounding tissue, quantitative analysis relies on the segmentation derived from a registered cine MRI acquisition. This requires an additional acquisition and is prone to imperfect spatial and temporal inter-scan alignment. Therefore, in this work we developed and evaluated deep learning-based methods to segment the left ventricle (LV) from 4D flow MRI directly.

Methods: We compared five deep learning-based approaches with different network structures, data pre-processing and feature fusion methods. For the data pre-processing, the 4D flow MRI data was reformatted into a stack of short-axis view slices. Two feature fusion approaches were proposed to integrate the features from magnitude and velocity images. The networks were trained and evaluated on an in-house dataset of 101 subjects with 67,567 2D images and 3030 3D volumes. The performance was evaluated using various metrics including Dice, average surface distance (ASD), end-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (LVEF), LV blood flow kinetic energy (KE) and LV flow components. The Monte Carlo dropout method was used to assess the confidence and to describe the uncertainty area in the segmentation results.

Results: Among the five models, the model combining 2D U-Net with late fusion method operating on short-axis reformatted 4D flow volumes achieved the best results with Dice of 84.52% and ASD of 3.14 mm. The best averaged absolute and relative error between manual and automated segmentation for EDV, ESV, LVEF and KE was 19.93 ml (10.39%), 17.38 ml (22.22%), 7.37% (13.93%) and 0.07 mJ (5.61%), respectively. Flow component results derived from automated segmentation showed high correlation and small average error compared to results derived from manual segmentation.

Conclusions: Deep learning-based methods can achieve accurate automated LV segmentation and subsequent quantification of volumetric and hemodynamic LV parameters from 4D flow MRI without requiring an additional cine MRI acquisition.

References
1.
Eriksson J, Carlhall C, Dyverfeldt P, Engvall J, Bolger A, Ebbers T . Semi-automatic quantification of 4D left ventricular blood flow. J Cardiovasc Magn Reson. 2010; 12:9. PMC: 2831022. DOI: 10.1186/1532-429X-12-9. View

2.
Berhane H, Scott M, Elbaz M, Jarvis K, McCarthy P, Carr J . Fully automated 3D aortic segmentation of 4D flow MRI for hemodynamic analysis using deep learning. Magn Reson Med. 2020; 84(4):2204-2218. PMC: 7724647. DOI: 10.1002/mrm.28257. View

3.
Uribe S, Beerbaum P, Sorensen T, Rasmusson A, Razavi R, Schaeffter T . Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating. Magn Reson Med. 2009; 62(4):984-92. DOI: 10.1002/mrm.22090. View

4.
Bustamante M, Viola F, Engvall J, Carlhall C, Ebbers T . Automatic Time-Resolved Cardiovascular Segmentation of 4D Flow MRI Using Deep Learning. J Magn Reson Imaging. 2022; 57(1):191-203. PMC: 10946960. DOI: 10.1002/jmri.28221. View

5.
Chen C, Bai W, Davies R, Bhuva A, Manisty C, Augusto J . Improving the Generalizability of Convolutional Neural Network-Based Segmentation on CMR Images. Front Cardiovasc Med. 2020; 7:105. PMC: 7344224. DOI: 10.3389/fcvm.2020.00105. View