» Articles » PMID: 18545999

Electromagnetic Field-based Navigation for Percutaneous Punctures on C-arm CT: Experimental Evaluation and Clinical Application

Overview
Journal Eur Radiol
Specialty Radiology
Date 2008 Jun 12
PMID 18545999
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study was to prospectively evaluate the needle visualization and placement error and use of an electromagnetic field-based tracking navigation device for puncture procedures based on C-arm CT (CACT) images. A commercially available navigation device was mounted on an angiographic X-ray system setup for CACT. After the target was defined, needle placement was performed under real-time visualization of the virtual needle in CACT images. The final, real needle position was assessed by CACT. Punctures were performed in phantoms (n = 76) and in twelve patients (eight biopsies, three drainages, one injection). Procedure times, system error, user error and total error were assessed. In phantoms, mean total error was 2.3 +/- 0.9 mm, user error was 1.4 +/- 0.8 mm and system error was 1.7 +/- 0.8 mm. In the patient study, the targeted puncture was successful in all twelve cases. The mean total error was 5.4 mm +/- 1.9 mm (maximum 8.1 mm), user error was 3.7 +/- 1.7 mm, system error was 3.2 +/- 1.4 mm and mean skin-to-target time was less than 1 min. The navigation device relying on CACT was accurate in terms of needle visualization and useful for needle placement under both experimental and clinical conditions. For more complex procedures, electromagnetic field-based tracking guidance might be of help in facilitating the puncture and reducing both the puncture risk and procedure time.

Citing Articles

Gyroscope-Assisted CT-Guided Puncture Improves Accuracy and Hit Rate Compared with Free-Hand Puncture: A Phantom Study.

Saeed S, Niehoff J, Boriesosdick J, Michael A, Schonbeck D, Woltjen M Cardiovasc Intervent Radiol. 2024; 47(12):1786-1794.

PMID: 39237781 DOI: 10.1007/s00270-024-03832-8.


Chinese expert consensus on cone-beam CT-guided diagnosis, localization and treatment for pulmonary nodules.

Xu D, Xie F, Zhang J, Chen H, Chen Z, Guan Z Thorac Cancer. 2024; 15(7):582-597.

PMID: 38337087 PMC: 10912555. DOI: 10.1111/1759-7714.15222.


A real-time 3D electromagnetic navigation system for percutaneous transforaminal endoscopic discectomy in patients with lumbar disc herniation: a retrospective study.

Wu B, Wei T, Yao Z, Yang S, Yao Y, Fu C BMC Musculoskelet Disord. 2022; 23(1):57.

PMID: 35039040 PMC: 8764808. DOI: 10.1186/s12891-022-05012-6.


Origami Lesion-Targeting Device for CT-Guided Interventions.

Taylor A, Xu S, Wood B, Tse Z J Imaging. 2021; 5(2).

PMID: 34460471 PMC: 8320902. DOI: 10.3390/jimaging5020023.


Ergonomics in Interventional Radiology: Awareness Is Mandatory.

Cornelis F, Razakamanantsoa L, Ammar M, Lehrer R, Haffaf I, El-Mouhadi S Medicina (Kaunas). 2021; 57(5).

PMID: 34069174 PMC: 8157181. DOI: 10.3390/medicina57050500.


References
1.
Gianfelice D, Lepanto L, Perreault P, Chartrand-Lefebvre C, Milette P . Value of CT fluoroscopy for percutaneous biopsy procedures. J Vasc Interv Radiol. 2000; 11(7):879-84. DOI: 10.1016/s1051-0443(07)61805-3. View

2.
Shimizu S, Shirato H, Aoyama H, Hashimoto S, Nishioka T, Yamazaki A . High-speed magnetic resonance imaging for four-dimensional treatment planning of conformal radiotherapy of moving body tumors. Int J Radiat Oncol Biol Phys. 2000; 48(2):471-4. DOI: 10.1016/s0360-3016(00)00624-6. View

3.
Wood B, Zhang H, Durrani A, Glossop N, Ranjan S, Lindisch D . Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study. J Vasc Interv Radiol. 2005; 16(4):493-505. PMC: 2375916. DOI: 10.1097/01.RVI.0000148827.62296.B4. View

4.
Giraud P, Reboul F, Clippe S, Garcia R, Carrie C, Campana F . [Respiration-gated radiotherapy: current techniques and potential benefits]. Cancer Radiother. 2004; 7 Suppl 1:15s-25s. View

5.
Nehmeh S, Erdi Y, Pan T, Yorke E, Mageras G, Rosenzweig K . Quantitation of respiratory motion during 4D-PET/CT acquisition. Med Phys. 2004; 31(6):1333-8. DOI: 10.1118/1.1739671. View