» Articles » PMID: 11232889

Feasibility of C-arm-supported CT Fluoroscopy in Percutaneous Abscess Drainage Procedures

Overview
Date 2001 Mar 10
PMID 11232889
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Evaluation of C-arm-supported CT fluoroscopy to facilitate percutaneous abscess drainage procedures.

Methods: Prospectively, 40 percutaneous drainage procedures were performed either with C-arm-supported CT fluoroscopy or with CT fluoroscopy alone. Hybrid imaging was performed on the CT couch after complementing a CT fluoroscopy scanner with a C-arm fluoroscopy unit. Procedure times, drainage revisions during follow-up, and postinterventional drainage periods were analyzed.

Results: When compared with exclusive CT fluoroscopic guidance, a median procedure time of 9 +/- 3.7 min versus 14.8 +/- 7.3 min was required for C-arm-supported CT fluoroscopy (p < 0.005, t-test). During follow-up, eight drainage catheters had to be revised within the exclusive CT fluoroscopy group, while only two revisions were necessary within the C-arm-supported CT fluoroscopy group. With C-arm-supported CT fluoroscopy, postinterventional drainage periods were reduced (median 13 vs 19 days; p < 0.001, t-test).

Conclusion: Compared with exclusive cross-sectional image guidance, C-arm-supported CT fluoroscopy seems to improve placement of abscess drainage catheters to possibly reduce procedure times, drainage catheter revisions, and postinterventional drainage periods.

Citing Articles

Development of subject-specific geometric spine model through use of automated active contour segmentation and kinematic constraint-limited registration.

Strickland C, Aguiar D, Nauman E, Talavage T J Digit Imaging. 2010; 24(5):926-42.

PMID: 20882395 PMC: 3180553. DOI: 10.1007/s10278-010-9336-z.


Image-guided percutaneous treatment of abdominal-pelvic abscesses: a 5-year experience.

Lagana D, Carrafiello G, Mangini M, Ianniello A, Giorgianni A, Nicotera P Radiol Med. 2008; 113(7):999-1007.

PMID: 18795233 DOI: 10.1007/s11547-008-0320-3.


Electromagnetic field-based navigation for percutaneous punctures on C-arm CT: experimental evaluation and clinical application.

Meyer B, Peter O, Nagel M, Hoheisel M, Frericks B, Wolf K Eur Radiol. 2008; 18(12):2855-64.

PMID: 18545999 DOI: 10.1007/s00330-008-1063-1.