Clive E W Hahn
Overview
Explore the profile of Clive E W Hahn including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
9
Citations
53
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Phan P, Zhang C, Geer D, Formenti F, Hahn C, Farmery A
IEEE J Transl Eng Health Med
. 2017 Dec;
5:2700209.
PMID: 29282434
The inspired sinewave technique is a noninvasive method to measure airway dead space, functional residual capacity, pulmonary blood flow, and lung inhomogeneity simultaneously. The purpose of this paper was to...
2.
Formenti F, Bommakanti N, Chen R, Cronin J, McPeak H, Holopherne-Doran D, et al.
Sci Rep
. 2017 Sep;
7(1):7499.
PMID: 28878215
Arterial oxygen partial pressure can increase during inspiration and decrease during expiration in the presence of a variable shunt fraction, such as with cyclical atelectasis, but it is generally presumed...
3.
Clifton L, Clifton D, Hahn C, Farmeryy A
IEEE J Transl Eng Health Med
. 2016 May;
1:1900108.
PMID: 27170849
Conventional methods for estimating cardiopulmonary variables usually require complex gas analyzers and the active co-operation of the patient. Therefore, they are not compatible with the crowded environment of the intensive...
4.
Formenti F, Farmery A, Hahn C
Respir Physiol Neurobiol
. 2014 Mar;
196:38.
PMID: 24583206
No abstract available.
5.
Formenti F, Chen R, McPeak H, Matejovic M, Farmery A, Hahn C
Respir Physiol Neurobiol
. 2013 Nov;
191:1-8.
PMID: 24184746
Two challenges in the management of Acute Respiratory Distress Syndrome are the difficulty in diagnosing cyclical atelectasis, and in individualising mechanical ventilation therapy in real-time. Commercial optical oxygen sensors can...
6.
Chen R, Formenti F, Obeid A, Hahn C, Farmery A
Physiol Meas
. 2013 Aug;
34(9):N71-81.
PMID: 23954921
The development and construction of a tapered-tip fibre-optic fluorescence based oxygen sensor is described. The sensor is suitable for fast and real-time monitoring of human breathing. The sensitivity and response...
7.
Clifton L, Clifton D, Hahn C, Farmery A
Respir Physiol Neurobiol
. 2013 May;
189(1):174-82.
PMID: 23702307
Conventional methods for monitoring lung function can require complex, or special, gas analysers, and may therefore not be practical in clinical areas such as the intensive care unit (ICU) or...
8.
Whiteley J, Gavaghan D, Hahn C
J Math Biol
. 2003 Jun;
47(1):79-99.
PMID: 12827449
Equations governing the transport of the gases oxygen and carbon dioxide inside the pulmonary capillaries are written down. By analysing these equations it is predicted that there will be negligible...
9.
Whiteley J, Gavaghan D, Hahn C
J Math Biol
. 2002 Jul;
44(6):503-22.
PMID: 12111100
The equations governing oxygen transport from blood to tissue are presented for a cylindrical tissue compartment, with blood flowing along a co-axial cylindrical capillary inside the tissue. These governing equations...