The Self-referencing Oxygen-selective Microelectrode: Detection of Transmembrane Oxygen Flux from Single Cells
Overview
Authors
Affiliations
A self-referencing, polarographic, oxygen-selective microelectrode was developed for measuring oxygen fluxes from single cells. This technique is based on the translational movement of the microelectrode at a known frequency through an oxygen gradient, between known points. The differential current of the electrode was converted into a directional measurement of flux using the Fick equation. Operational characteristics of the technique were determined using artificial gradients. Calculated oxygen flux values matched theoretical values derived from static measurements. A test preparation, an isolated neuron, yielded an oxygen flux of 11.46+/-1.43 pmol cm-2 s-1 (mean +/- s.e.m.), a value in agreement with those available in the literature for single cells. Microinjection of metabolic substrates or a metabolic uncoupler increased oxygen flux, whereas microinjection of KCN decreased oxygen flux. In the filamentous alga Spirogyra greveilina, the probe could easily differentiate a 16.6% difference in oxygen flux with respect to the position of the spiral chloroplast (13.3+/-0.4 pmol cm-2 s-1 at the chloroplast and 11.4+/-0.4 pmol cm-2 s-1 between chloroplasts), despite the fact that these positions averaged only 10.6+/-1.8 microm apart (means +/- s.e.m.). A light response experiment showed real-time changes in measured oxygen flux correlated with changes in lighting. Taken together, these results show that the self-referencing oxygen microelectrode technique can be used to detect local oxygen fluxes with a high level of sensitivity and spatial resolution in real time. The oxygen fluxes detected reliably correlated with the metabolic state of the cell.
Fundamental Neurochemistry Review: Microglial immunometabolism in traumatic brain injury.
Strogulski N, Portela L, Polster B, Loane D J Neurochem. 2023; 167(2):129-153.
PMID: 37759406 PMC: 10655864. DOI: 10.1111/jnc.15959.
Mitochondrial leak metabolism induces the Spemann-Mangold Organizer via Hif-1α in Xenopus.
MacColl Garfinkel A, Mnatsakanyan N, Patel J, Wills A, Shteyman A, Smith P Dev Cell. 2023; 58(22):2597-2613.e4.
PMID: 37673063 PMC: 10840693. DOI: 10.1016/j.devcel.2023.08.015.
Vadgama P Sensors (Basel). 2020; 20(11).
PMID: 32498360 PMC: 7308849. DOI: 10.3390/s20113149.
Ferreira F, Luxardi G, Reid B, Ma L, Raghunathan V, Zhao M Nat Protoc. 2020; 15(2):207-235.
PMID: 31925402 PMC: 7980673. DOI: 10.1038/s41596-019-0231-x.
Chen R, Park H, Mnatsakanyan N, Niu Y, Licznerski P, Wu J Cell Death Dis. 2019; 10(6):469.
PMID: 31197129 PMC: 6565618. DOI: 10.1038/s41419-019-1679-x.