» Articles » PMID: 32498360

Monitoring with In Vivo Electrochemical Sensors: Navigating the Complexities of Blood and Tissue Reactivity

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 Jun 6
PMID 32498360
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The disruptive action of an acute or critical illness is frequently manifest through rapid biochemical changes that may require continuous monitoring. Within these changes, resides trend information of predictive value, including responsiveness to therapy. In contrast to physical variables, biochemical parameters monitored on a continuous basis are a largely untapped resource because of the lack of clinically usable monitoring systems. This is despite the huge testing repertoire opening up in recent years in relation to discrete biochemical measurements. Electrochemical sensors offer one of the few routes to obtaining continuous readout and, moreover, as implantable devices information referable to specific tissue locations. This review focuses on new biological insights that have been secured through in vivo electrochemical sensors. In addition, the challenges of operating in a reactive, biological, sample matrix are highlighted. Specific attention is given to the choreographed host rejection response, as evidenced in blood and tissue, and how this limits both sensor life time and reliability of operation. Examples will be based around ion, O, glucose, and lactate sensors, because of the fundamental importance of this group to acute health care.

Citing Articles

Circadian clock communication during homeostasis and ageing.

Mortimer T, Smith J, Munoz-Canoves P, Benitah S Nat Rev Mol Cell Biol. 2025; .

PMID: 39753699 DOI: 10.1038/s41580-024-00802-3.


Electrochemical Detection of Gasotransmitters: Status and Roadmap.

Herrald A, Ambrogi E, Mirica K ACS Sens. 2024; 9(4):1682-1705.

PMID: 38593007 PMC: 11196117. DOI: 10.1021/acssensors.3c02529.


Towards Multiplexed and Multimodal Biosensor Platforms in Real-Time Monitoring of Metabolic Disorders.

Chu S, Nguyen H, Zhang J, Tabassum S, Cao H Sensors (Basel). 2022; 22(14).

PMID: 35890880 PMC: 9323394. DOI: 10.3390/s22145200.


Real-Time Monitoring of Blood Parameters in the Intensive Care Unit: State-of-the-Art and Perspectives.

Bockholt R, Paschke S, Heubner L, Ibarlucea B, Laupp A, Janicijevic Z J Clin Med. 2022; 11(9).

PMID: 35566534 PMC: 9100654. DOI: 10.3390/jcm11092408.


Biosensors-Recent Advances and Future Challenges.

Bollella P, Katz E Sensors (Basel). 2020; 20(22).

PMID: 33233539 PMC: 7699460. DOI: 10.3390/s20226645.

References
1.
Modinger Y, Teixeira G, Neidlinger-Wilke C, Ignatius A . Role of the Complement System in the Response to Orthopedic Biomaterials. Int J Mol Sci. 2018; 19(11). PMC: 6274916. DOI: 10.3390/ijms19113367. View

2.
LANG D, Matthews D, Peto J, Turner R . Cyclic oscillations of basal plasma glucose and insulin concentrations in human beings. N Engl J Med. 1979; 301(19):1023-7. DOI: 10.1056/NEJM197911083011903. View

3.
McClatchey P, McClain E, Williams I, Malabanan C, James F, Lord P . Fibrotic Encapsulation Is the Dominant Source of Continuous Glucose Monitor Delays. Diabetes. 2019; 68(10):1892-1901. PMC: 6754243. DOI: 10.2337/db19-0229. View

4.
QUINN C, Connor R, Heller A . Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors. Biomaterials. 1998; 18(24):1665-70. DOI: 10.1016/s0142-9612(97)00125-7. View

5.
Vovenko E . Distribution of oxygen tension on the surface of arterioles, capillaries and venules of brain cortex and in tissue in normoxia: an experimental study on rats. Pflugers Arch. 1999; 437(4):617-23. DOI: 10.1007/s004240050825. View