» Articles » PMID: 9326125

Aquaflo Pump Vs FMS 4 Pump for Shoulder Arthroscopic Surgery

Overview
Specialty General Surgery
Date 1997 Oct 23
PMID 9326125
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

A prospective controlled trial was carried out to compare two different fluid delivery systems used for shoulder arthroscopy. One an advanced pump system that controls both pressure and flow of fluid delivered, the other an air-driven diaphragm pump that only controls fluid pressure. Blood loss, presence of bleeding vessels and visual clarity were parameters used to assess the pump systems. There was no difference between the pumps in straightforward shoulder procedures. However, complicated and prolonged procedures benefited from the use of the advanced pump system.

Citing Articles

The efficacy of preoperative tranexamic acid administration among patients undergoing arthroscopic rotator cuff repair: A systematic review and meta-analysis of randomized controlled trials.

Alyousef M, Alaqaili S, Alzayer M, Alsultan A, Abusultan A, Alzahrani M Shoulder Elbow. 2024; 16(6):595-604.

PMID: 39650266 PMC: 11622356. DOI: 10.1177/17585732231207972.


Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid.

Kawaguchi S, Fukuta S, Kano M, Sairyo K Asia Pac J Sports Med Arthrosc Rehabil Technol. 2023; 31:6-10.

PMID: 36820053 PMC: 9937805. DOI: 10.1016/j.asmart.2023.01.001.


Cost Effective Technique of Shoulder Arthroscopy Without the Use of Epinephrine in Irrigation Solution.

Stetson W, Morgan S, Polinsky S, Chung B, Hung N Arthrosc Tech. 2021; 10(2):e411-e418.

PMID: 33680773 PMC: 7917405. DOI: 10.1016/j.eats.2020.10.025.


Comparison of the efficacy of irrigation with epinephrine or tranexamic acid on visual clarity during arthroscopic rotator cuff repair: A double-blind, randomized-controlled study.

Bayram E, Yildirim C, Erturk A, Yilmaz M, Atlihan D Jt Dis Relat Surg. 2021; 32(1):115-121.

PMID: 33463426 PMC: 8073435. DOI: 10.5606/ehc.2021.78393.


Performance of arthroscopic irrigation systems assessed with automatic blood detection.

Tuijthof G, de Vaal M, Sierevelt I, Blankevoort L, van der List M Knee Surg Sports Traumatol Arthrosc. 2011; 19(11):1948-54.

PMID: 21479643 PMC: 3195766. DOI: 10.1007/s00167-011-1495-z.


References
1.
Weisleder L . Fluid pump systems for arthroscopy: a comparison of pressure control versus pressure and flow control. Arthroscopy. 1995; 11(5):591-5. DOI: 10.1016/0749-8063(95)90137-x. View

2.
Morgan C . Fluid delivery systems for arthroscopy. Arthroscopy. 1987; 3(4):288-91. DOI: 10.1016/s0749-8063(87)80126-3. View