» Articles » PMID: 8534302

Fluid Pump Systems for Arthroscopy: a Comparison of Pressure Control Versus Pressure and Flow Control

Overview
Journal Arthroscopy
Specialty Orthopedics
Date 1995 Oct 1
PMID 8534302
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

We set out to compare two pump systems, one in which pressure alone could be controlled and the second in which pressure and flow could be controlled separately. Assessments were carried out by two observers independently. A variety of arthroscopic procedures were studied including arthroscopy of the knee, anterior cruciate ligament reconstruction, arthroscopy and acromioplasty of the shoulder, and arthroscopy of the elbow and ankle. We found that both systems used a similar amount of fluid. However, the operative time was significantly decreased with separate control of pressure and flow. This was related to the fact that there was better visualization and better technical ease with the latter pump. There was significantly less extravasation in the soft tissues. Therefore, based on our assessment, pumps that separately control pressure and flow are significantly better than pumps that control pressure alone. There is distinct advantage in less operative time, greater visualization, technical ease, and less soft tissue extravasation.

Citing Articles

Efficacy of tranexamic acid in improving visual clarity and operative time of arthroscopic rotator cuff repair: A systematic review and meta-analysis.

Qian Y, Jiang A, Yan J, Zhang S, Zhu S Acta Orthop Traumatol Turc. 2025; 58(6):318-325.

PMID: 39873591 PMC: 11740232. DOI: 10.5152/j.aott.2024.24008.


Improving visualization in shoulder arthroscopy.

McDermott E, Tennent D, Song D Clin Shoulder Elb. 2023; 26(4):455-461.

PMID: 37088880 PMC: 10698137. DOI: 10.5397/cise.2022.01291.


Reduction of perioperative blood loss and operating time for arthroscopic rotator cuff repair by intravenous administration of tranexamic acid.

Kawaguchi S, Fukuta S, Kano M, Sairyo K Asia Pac J Sports Med Arthrosc Rehabil Technol. 2023; 31:6-10.

PMID: 36820053 PMC: 9937805. DOI: 10.1016/j.asmart.2023.01.001.


Midterm Safety of Carbon Dioxide Insufflation of the Knee During Arthroscopic Cartilage-Based Procedures.

Penton J, Flick T, Savoie 3rd F, Heard W, Sherman W Orthop J Sports Med. 2021; 9(10):23259671211035454.

PMID: 34692876 PMC: 8527579. DOI: 10.1177/23259671211035454.


Intra-operative effect of interscalene brachial plexus block to arthroscopic rotator cuff repair surgery.

Choi S, Kim T, Kwon Y, Kang H Int Orthop. 2018; 43(9):2117-2124.

PMID: 30318561 DOI: 10.1007/s00264-018-4199-x.