» Articles » PMID: 8968612

Biotechnology at Low Reynolds Numbers

Overview
Journal Biophys J
Publisher Cell Press
Specialty Biophysics
Date 1996 Dec 1
PMID 8968612
Citations 67
Authors
Affiliations
Soon will be listed here.
Abstract

The shrinking of liquid handling systems to the micron and submicron size range entails moving into the area of small Reynolds numbers. The fluid dynamics in this regime are very different from the macroscale. We present an intuitive explanation of how the different physics of small Reynolds numbers flow, along with microscopic sizes, can influence device design, and give examples from our own work using fluid flow in microfabricated devices designed for biological processing.

Citing Articles

Range of effectiveness of hydraulic diameter model as an analytical solution for rectangular microchannels.

Kobayashi K, Sakamoto K Heliyon. 2025; 11(1):e41498.

PMID: 39850432 PMC: 11755038. DOI: 10.1016/j.heliyon.2024.e41498.


Asymmetric fluid flow in helical pipes inspired by shark intestines.

Levin I, Sadaba N, Nelson A, Keller S Proc Natl Acad Sci U S A. 2024; 121(40):e2406481121.

PMID: 39316056 PMC: 11459177. DOI: 10.1073/pnas.2406481121.


Microfluidic technology for cell biology-related applications: a review.

Mukherjee J, Chaturvedi D, Mishra S, Jain R, Dandekar P J Biol Phys. 2023; 50(1):1-27.

PMID: 38055086 PMC: 10864244. DOI: 10.1007/s10867-023-09646-y.


An in silico model of the capturing of magnetic nanoparticles in tumour spheroids in the presence of flow.

Wirthl B, Janko C, Lyer S, Schrefler B, Alexiou C, Wall W Biomed Microdevices. 2023; 26(1):1.

PMID: 38008813 PMC: 10678808. DOI: 10.1007/s10544-023-00685-9.


A multiplexed microfluidic continuous-flow electroporation system for efficient cell transfection.

VanderBurgh J, Corso G, Levy S, Craighead H Res Sq. 2023; .

PMID: 37986928 PMC: 10659555. DOI: 10.21203/rs.3.rs-3538613/v1.


References
1.
BOCQUET , BARRAT . Hydrodynamic boundary conditions and correlation functions of confined fluids. Phys Rev Lett. 1993; 70(18):2726-2729. DOI: 10.1103/PhysRevLett.70.2726. View

2.
Volkmuth W, Austin R . DNA electrophoresis in microlithographic arrays. Nature. 1992; 358(6387):600-2. DOI: 10.1038/358600a0. View

3.
Brody J, Han Y, Austin R, Bitensky M . Deformation and flow of red blood cells in a synthetic lattice: evidence for an active cytoskeleton. Biophys J. 1995; 68(6):2224-32. PMC: 1282133. DOI: 10.1016/S0006-3495(95)80443-1. View

4.
Wilding P, Shoffner M, Kricka L . PCR in a silicon microstructure. Clin Chem. 1994; 40(9):1815-8. View

5.
He , Kahanda , Wong . Roughness of wetting fluid invasion fronts in porous media. Phys Rev Lett. 1992; 69(26):3731-3734. DOI: 10.1103/PhysRevLett.69.3731. View