A Cost-analysis of Computed Radiography and Picture Archiving and Communication Systems in Portable Radiography

Overview
Journal J Digit Imaging
Publisher Springer
Date 1996 Feb 1
PMID 8814768
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

A total of 40,000 portable examinations are performed each year at Shands Hospital (Gainesville, FL), a 570-bed teaching hospital. Radiographs are obtained using a screen-film combination with the films digitized for transmission to displays in four intensive care units. A cost-analysis of replacing screen-film with computed radiography (CR) integrated into a filmless picture archiving and communication system (PACS) network was performed. Equipment requirements included two CR units, three high-resolution dual monitor displays, and an archive to store 3 months of image data. The capital costs were amortized over a 5-year period. Capital and operating costs of the proposed expansion to the existing PACS network, together with anticipated cost savings, were determined. The maximum data transfer rate for portable examinations was 150 MByte per hour and approximately 400 GByte of image data are generated each year. These figures were used to determine the hardware requirements for handling the acquisition, transfer, and display of the images. Annual costs of the proposed expansion were about $220,000. Cost savings were achieved by elimination of film, including its handling by technologists/library clerks, and amounted to about $200,000 per year.

Citing Articles

A filmless radiology teaching conference system for pertinent displaying and image searching.

Abe K, Narata M, Tanaka I, Takahashi M, Igarashi A, Sasaki T J Digit Imaging. 2008; 22(6):598-604.

PMID: 18196340 PMC: 3043734. DOI: 10.1007/s10278-007-9095-7.


Enterprise-wide CR implementation: the Shands Healthcare System experience.

Arreola M, Rill L J Digit Imaging. 2003; 16(2):173-9.

PMID: 12964055 PMC: 3046469. DOI: 10.1007/s10278-003-1653-z.


Support line and tube visibility in chest examinations using computed radiography.

Huda W, Belden C, Webb L, Palmer C J Digit Imaging. 1997; 10(3):126-31.

PMID: 9268908 PMC: 3452951. DOI: 10.1007/BF03168600.

References
1.
Sanada S, Doi K, Xu X, Yin F, Giger M, Macmahon H . Comparison of imaging properties of a computed radiography system and screen-film systems. Med Phys. 1991; 18(3):414-20. DOI: 10.1118/1.596688. View

2.
Schaefer C, Greene R, Oestmann J, Kamalsky J, Hall D, Llewellyn H . Improved control of image optical density with low-dose digital and conventional radiography in bedside imaging. Radiology. 1989; 173(3):713-6. DOI: 10.1148/radiology.173.3.2813775. View

3.
FRIEDENBERG R . Potential clinical problems associated with PACS. Radiology. 1993; 189(1):55A-57A. DOI: 10.1148/radiology.189.1.55a. View

4.
Sonoda M, Takano M, Miyahara J, Kato H . Computed radiography utilizing scanning laser stimulated luminescence. Radiology. 1983; 148(3):833-8. DOI: 10.1148/radiology.148.3.6878707. View

5.
Schaefer C, Prokop M . Storage phosphor radiography of the chest. Radiology. 1993; 186(2):314-5. DOI: 10.1148/radiology.186.2.8421725. View