Biocompatibility of Polymer-coated Oversized Metallic Stents Implanted in Normal Porcine Coronary Arteries

Overview
Journal Atherosclerosis
Publisher Elsevier
Date 1995 Apr 7
PMID 7605369
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Polymer coatings have been suggested to decrease the thrombogenicity of metallic intravascular stents. The purpose of the present study was to investigate the intimal response to two different polymers when used as coatings for stents implanted in normal porcine coronary arteries. Non-articulated stainless steel-slotted tube stents were coated with either a biodegradable poly(organo)phosphazene with amino-acid ester side groups or a biostable polyurethane prepared from an amphiphilic polyether, dephenylmethane-4,4'-diisocyanate and butane diol as chain extender. In order to induce vascular wall injury, the stents were deployed using an oversized balloon. At 6 weeks follow-up, the angiographic luminal diameter measured in four polyurethane-coated stents and in six bare metallic stents was similar and 20% less than immediately post-stenting. However, in four polyphosphazene-coated stents the difference was 65% (P = 0.01 when compared to bare metal). At post-mortem morphometry the degree of luminal area stenosis was also similar in polyurethane-coated and in bare metallic stents (32 +/- 7.6% vs. 39 +/- 14%, NS) but reached 81 +/- 19% in polyphosphazene-coated stents (P < 0.03 when compared to bare metal). Thus, poly(organo)phosphazene induced a more pronounced histiolymphocytic and fibromuscular reaction than amphiphilic polyurethane, which appeared to be promising as biocompatible stent coating and, consequently, as a potential carrier for vasoactive drugs.

Citing Articles

On the importance of modeling balloon folding, pleating, and stent crimping: An FE study comparing experimental inflation tests.

Geith M, Swidergal K, Hochholdinger B, Schratzenstaller T, Wagner M, Holzapfel G Int J Numer Method Biomed Eng. 2019; 35(11):e3249.

PMID: 31400057 PMC: 9285761. DOI: 10.1002/cnm.3249.


Effect of nonionic surfactants in release media on accelerated release profile of sirolimus eluting stents with biodegradable polymeric coating.

Raval A, Bahadur P, Raval A J Pharm Anal. 2018; 8(1):45-54.

PMID: 29568667 PMC: 5859125. DOI: 10.1016/j.jpha.2017.06.002.


Electrografting of a biodegradable layer as a primer adhesion coating onto a metallic stent: in vitro and in vivo evaluations.

Vergnol G, Renard E, Haroun F, Guerin P, Seron A, Bureau C J Mater Sci Mater Med. 2013; 24(12):2729-39.

PMID: 23904056 DOI: 10.1007/s10856-013-5015-1.


Use of a novel anti-proliferative compound coated on a biopolymer to mitigate platelet-derived growth factor-induced proliferation in human aortic smooth muscle cells: comparison with sirolimus.

Tang Y, Pandey A, Kolmakova A, Wang X, Venkatraman S, Chatterjee S Glycoconj J. 2008; 26(6):721-32.

PMID: 18853254 DOI: 10.1007/s10719-008-9192-y.


Preparation and characterization of rapamycin-loaded PLGA coating stent.

Pan C, Tang J, Weng Y, Wang J, Huang N J Mater Sci Mater Med. 2007; 18(11):2193-8.

PMID: 17607513 DOI: 10.1007/s10856-007-3075-9.