Total Body Water Measurement in Humans with 18O and 2H Labeled Water

Overview
Journal Am J Clin Nutr
Publisher Elsevier
Date 1980 Dec 1
PMID 6776801
Citations 101
Authors
Affiliations
Soon will be listed here.
Abstract

Deuterium or tritium labeled water traditionally has been used for the measurement of total body water by application of the dilution principle. However, these methods have not enjoyed wide clinical use. The use of deuterium is hampered by the tedious and time consuming nature of the analysis while the use of tritium involves a radiation hazard. In addition, exchange of the label with nonaqueous hydrogen in the body raises questions about the accuracy of total body water values. To determine if water labeled with the stable isotope 18O can yield faster and more accurate results, total body water was measured simultaneously using water labeled with both 18O and 2H. The 18O and 3H dilutions were measured by mass spectrometry. The relative precision of the body water value using the 18O method was 2% for both serum and breath analysis. The 18O was fully equilibrated within 2 to 3 hr after administration, and results from the analysis of breath CO2 could be readily obtained within 1 hr after sampling. The H2(18)O dilution space averaged 3.0% (SE = 0.4) less than the 2HHO dilution space, because the latter exchanges with nonaqueous hydrogen. For this reason, the H2(18)O dilution should be a more accurate measure of total body water than the 3HHO dilution.

Citing Articles

Evaluation of fluid status in patients with acromegaly through bioelectrical impedance vector analysis: a cross-sectional study.

Varaldo E, Prencipe N, Berton A, Cuboni D, Aversa L, Sibilla M J Endocrinol Invest. 2025; .

PMID: 39954196 DOI: 10.1007/s40618-025-02541-4.


Evaluation of a Rapid Four-Compartment Model and Stand-Alone Methods in Hispanic Adults.

Nickerson B, Tinsley G, Park K, Nassar B, Czerwinski S J Nutr. 2023; 153(8):2154-2162.

PMID: 37414360 PMC: 10447617. DOI: 10.1016/j.tjnut.2023.06.041.


Validation of the SMH Equations for the Estimation of the Total Body Water Volume in Hemodialysis Patients.

Noori N, Sharma Parpia A, Wald R, Goldstein M Can J Kidney Health Dis. 2022; 9:20543581221137180.

PMID: 36438438 PMC: 9685218. DOI: 10.1177/20543581221137180.


Hypoxia briefly increases diuresis but reduces plasma volume by fluid redistribution in women.

Roche J, Rasmussen P, Gatterer H, Roveri G, Turner R, van Hall G Am J Physiol Heart Circ Physiol. 2022; 323(6):H1068-H1079.

PMID: 36269645 PMC: 9678412. DOI: 10.1152/ajpheart.00394.2022.


Association between classic and specific bioimpedance vector analysis and sarcopenia in older adults: a cross-sectional study.

Rossini-Venturini A, Abdalla P, Giacomo Fassini P, Santos A, Tasinafo Junior M, Alves T BMC Sports Sci Med Rehabil. 2022; 14(1):170.

PMID: 36104722 PMC: 9476257. DOI: 10.1186/s13102-022-00559-2.