Validity of Body-Composition Methods Across Racial and Ethnic Populations
Overview
Affiliations
Multi-compartment body-composition models that divide the body into its multiple constituents are the criterion method for measuring body fat percentage, fat mass, and fat-free mass. However, 2- and 3-compartment body-composition devices such as air displacement plethysmography (ADP), DXA, and bioelectrical impedance devices [bioelectrical impedance analysis (BIA)] are more commonly used. Accurate measures depend on several assumptions, including constant hydration, body proportion, fat-free body density, and population characteristics. Investigations evaluating body composition in racial and ethnic minorities have observed differences in the aforementioned components between cohorts. Consequently, for racial/ethnic minority populations, estimates of body composition may not be valid. The purpose of this review was to comprehensively examine the validity of common body-composition devices in multi-ethnic samples (samples including >1 race/ethnicity) and in African-American, Hispanic, Asian, and Native American populations. Based on the literature, DXA produces valid results in multi-ethnic samples and ADP is valid for Hispanic and African American males when utilizing race-specific equations. However, for DXA and ADP, there is a need for validity investigations that include larger, more racially diverse samples, specifically including Hispanic/Latinx, Asian, Native American adults, and African-American females. Technology has advanced significantly since initial validity studies were conducted; therefore, conclusions are based on outdated models and software. For BIA, body-composition measures may be valid in a multi-ethnic sample, but the literature demonstrates disparate results between races/ethnicities. For BIA and ADP, the majority of studies have utilized DXA or hydrostatic weighing as the criterion to determine validity; additional studies utilizing a multi-compartment model criterion are essential to evaluate accuracy. Validity studies evaluating more recent technology in larger, more racially/ethnically diverse samples may improve our ability to select the appropriate method to accurately assess body composition in each racial/ethnic population.
McClung H, Bartlett P, Spiering B, Foulis S, Oliver T, Walker L Int J Obes (Lond). 2025; .
PMID: 40016560 DOI: 10.1038/s41366-024-01701-5.
A Decade of Progress in Ultrasound Assessments of Subcutaneous and Total Body Fat: A Scoping Review.
Neagu M, Neagu A Life (Basel). 2025; 15(2).
PMID: 40003645 PMC: 11856862. DOI: 10.3390/life15020236.
Zhang J, Cao W, Xu J, Wang H, Luo R, Gan Q Nutrients. 2025; 17(2).
PMID: 39861494 PMC: 11768175. DOI: 10.3390/nu17020364.
Advances in the estimation of body fat percentage using an artificial intelligence 2D-photo method.
Ferreira T, Salvador I, Pessanha C, da Silva R, Pereira A, Horst M NPJ Digit Med. 2025; 8(1):43.
PMID: 39827323 PMC: 11743147. DOI: 10.1038/s41746-024-01380-6.
Dong H, Cheng H, Xiong J, Liu L, Huang Y, Shan X J Glob Health. 2024; 14:04247.
PMID: 39545353 PMC: 11565468. DOI: 10.7189/jogh.14.04247.