» Articles » PMID: 4338005

Virus in Water. II. Evaluation of Membrane Cartridge Filters for Recovering Low Multiplicities of Poliovirus from Water

Overview
Journal Appl Microbiol
Specialty Microbiology
Date 1972 May 1
PMID 4338005
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

The efficiency of a Millitube MF cartridge filter, a membrane filter, for recovery of poliovirus from 100-gal volumes of both fresh (tap) and estuarine water was determined. In the high multiplicity of virus input-output experiments, recovery of 97% or greater of input virus was achieved in both types of water when the final concentration of divalent cation as Mg(2+) was 1,200 mug/ml and the pH was 4.5. Virus was effectively eluted from the membrane cartridge with 5x nutrient broth in 0.05 M carbonate-bicarbonate buffer at pH 9.0. Four elutions of 250 ml each were used. In the low multiplicity of virus input-output experiments under the same cationic and pH conditions, up to 67% of the input virus was recovered when the virus was further concentrated from the eluates by the aqueous polymer two-phase separation technique. The volume reduction was 126,000-190,000 to 1. The use of the combined techniques, i.e., membrane adsorption followed by aqueous polymer two-phase separation, provided a highly sensitive, simple, and remarkably reliable sequential methodology for the quantitative recovery of poliovirus occurring at multiplicities as low as 1 to 2 plaque-forming units per 5 gal of water.

Citing Articles

Evaluation of Secondary Concentration Methods for Poliovirus Detection in Wastewater.

Falman J, Fagnant-Sperati C, Kossik A, Boyle D, Meschke J Food Environ Virol. 2019; 11(1):20-31.

PMID: 30612304 PMC: 6394643. DOI: 10.1007/s12560-018-09364-y.


EPA Method 1615. Measurement of enterovirus and norovirus occurrence in water by culture and RT-qPCR. I. Collection of virus samples.

Fout G, Cashdollar J, Varughese E, Parshionikar S, Grimm A J Vis Exp. 2015; (97).

PMID: 25867928 PMC: 4401389. DOI: 10.3791/52067.


Concentration and recovery of viruses from water: a comprehensive review.

Ikner L, Gerba C, Bright K Food Environ Virol. 2013; 4(2):41-67.

PMID: 23412811 DOI: 10.1007/s12560-012-9080-2.


Procedure for recovery of enteroviruses from the Japanese cockle Tapes japonica.

Johnson K, Cooper R, Straube D Appl Environ Microbiol. 1981; 41(4):932-5.

PMID: 6263186 PMC: 243836. DOI: 10.1128/aem.41.4.932-935.1981.


Poliovirus concentration from tap water with electropositive adsorbent filters.

Sobsey M, Glass J Appl Environ Microbiol. 1980; 40(2):201-10.

PMID: 6258472 PMC: 291553. DOI: 10.1128/aem.40.2.201-210.1980.


References
1.
HAMBLET F, Hill W, Akin E . Effect of plaque assay diluent upon enumeration of poliovirus type 1. Appl Microbiol. 1967; 15(1):208. PMC: 546875. DOI: 10.1128/am.15.1.208-.1967. View

2.
Wallis C, Melnick J . Concentration of viruses from sewage by adsorption on millipore membranes. Bull World Health Organ. 1967; 36(2):219-25. PMC: 2476373. View

3.
Hill Jr W, HAMBLET F, Benton W . Inactivation of poliovirus type 1 by the Kelly-Purdy ultraviolet seawater treatment unit. Appl Microbiol. 1969; 17(1):1-6. PMC: 377600. DOI: 10.1128/am.17.1.1-6.1969. View

4.
RAO N, LABZOFFSKY N . A simple method for the detection of low concentration of viruses in large volumes of water by the membrane filter technique. Can J Microbiol. 1969; 15(5):399-403. DOI: 10.1139/m69-071. View

5.
Anderson N, Waters D, Nunley C, Gibson R, Schilling R, Denny E . K-series centrifuges. I. Development of the K-II continuous-sample-flow-with-banding centrifuge system for vaccine purification. Anal Biochem. 1969; 32(3):460-94. DOI: 10.1016/s0003-2697(69)80014-x. View