Effect of Abutment Material on AMMP-8 Levels in Peri-Implant Sulcular Fluid over 12 Months: A Randomized Controlled Trial

Overview
Specialty Radiology
Date 2025 Feb 13
PMID 39941195
Authors
Affiliations
Soon will be listed here.
Abstract

The long-term success of dental implants can be influenced by the material properties of abutments and their interaction with peri-implant tissues. This study investigates the impact of three abutment materials-titanium (Ti), zirconium oxide (Zr), and polymethylmethacrylate (PMMA)-on the inflammatory response in peri-implant sulcular fluid (PISF), using active-matrix metalloproteinase-8 (aMMP-8) as a biomarker. In this prospective, randomized clinical trial, 30 patients were assigned to Ti, Zr, or PMMA abutment groups. PISF samples were collected at predefined intervals over 12 months and analyzed for aMMP-8 levels using enzyme-linked immunosorbent assays (ELISA). Clinical parameters (probing depth, bleeding on probing, and plaque index) and radiographic assessments of bone resorption were also evaluated. Two weeks after implant uncovering, baseline aMMP-8 levels varied significantly among materials, with Zr demonstrating the highest levels. Over time (2, 3, 6 and 12 months after implant uncovering), aMMP-8 levels decreased across all groups, with no significant differences observed at 12 months. Radiographic assessments indicated no statistically significant differences in bone resorption, with clinical parameters remaining comparable across all groups. Initial inflammatory responses to abutment materials may vary; however, all tested materials-Ti, Zr, and PMMA-showed long-term biocompatibility and supported healthy peri-implant tissue integration. These findings indicate that selecting any of the tested abutment materials does not significantly affect long-term peri-implant health.

References
1.
Groessner-Schreiber B, Hannig M, Duck A, Griepentrog M, Wenderoth D . Do different implant surfaces exposed in the oral cavity of humans show different biofilm compositions and activities?. Eur J Oral Sci. 2004; 112(6):516-22. DOI: 10.1111/j.1600-0722.2004.00171.x. View

2.
Zhang L, Li X, Yan H, Huang L . Salivary matrix metalloproteinase (MMP)-8 as a biomarker for periodontitis: A PRISMA-compliant systematic review and meta-analysis. Medicine (Baltimore). 2018; 97(3):e9642. PMC: 5779768. DOI: 10.1097/MD.0000000000009642. View

3.
Lahteenmaki H, Tervahartiala T, Raisanen I, Parnanen P, Mauramo M, Gupta S . Active MMP-8 point-of-care (PoC)/chairside enzyme-test as an adjunctive tool for early and real-time diagnosis of peri-implantitis. Clin Exp Dent Res. 2022; 8(2):485-496. PMC: 9033547. DOI: 10.1002/cre2.537. View

4.
Canullo L, Menini M, Santori G, Rakic M, Sculean A, Pesce P . Titanium abutment surface modifications and peri-implant tissue behavior: a systematic review and meta-analysis. Clin Oral Investig. 2020; 24(3):1113-1124. DOI: 10.1007/s00784-020-03210-x. View

5.
Lekholm U, Adell R, Lindhe J, Branemark P, Eriksson B, Rockler B . Marginal tissue reactions at osseointegrated titanium fixtures. (II) A cross-sectional retrospective study. Int J Oral Maxillofac Surg. 1986; 15(1):53-61. DOI: 10.1016/s0300-9785(86)80011-4. View