» Articles » PMID: 39169901

"Ultralow-dose" CT Without Sedation in Pediatric Patients With Neuromuscular Scoliosis

Overview
Specialty Pediatrics
Date 2024 Aug 22
PMID 39169901
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Children with neuromuscular scoliosis undergoing scoliosis surgery face substantial rates of complications. To mitigate surgical risks such as blood loss in pediatric patients with neuromuscular scoliosis, this study focuses on enabling instrumentation planning for their abnormal vertebral and pelvic anatomy and osteopenia. This study assessed the feasibility of an "ultralow-dose" CT (ULD CT) protocol without sedation in pediatric patients with neuromuscular scoliosis who often have comorbid movement disorders. Our prospective quality improvement study aims: (1) to determine if ULD CT without sedation is feasible in this patient group; (2) to quantify the radiation dose from ULD CT and compare it with preoperative spine radiographs (XR); and (3) to assess if ULD CT allows accurate anatomical assessment and intraoperative navigation given the prevalence of movement disorders.

Methods: Children with neuromuscular scoliosis underwent spine XR and ULD CT scans. Chart reviews assessed disease etiology and comorbidities. Radiation dose was quantified through Monte-Carlo simulations giving dose indices and effective dose, with statistical analysis done using a paired student's t -test (α=0.05). CT image quality was assessed for its use in preoperative planning and intraoperative navigation.

Results: Fourteen patients (5 males, 9 females, average age 14±3 y) participated. One patient needed sedation due to autism spectrum disorder and global developmental delay. The radiation dose for spine XR was 0.5±0.2 mSv, and ULD CT was 0.6±0.1 mSv. There was no statistically significant difference in radiation doses between methods. All ULD CT scans had adequate quality for preoperative assessment of pedicle diameter and orientation, obstacles impeding pedicle entry, S2 Alar-Iliac screw orientation, and intraoperative navigation.

Conclusions: ULD CT without sedation is feasible for children with neuromuscular scoliosis. Radiation doses were comparable to standard radiographs. ULD CT provided accurate anatomical assessments and supported intraoperative navigation, proving beneficial despite movement disorders in these patients.

Level Of Evidence: Level 2-Development of diagnostic criteria on basis of consecutive patients (with universally applied reference widely accepted standard).

References
1.
. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007; 37(2-4):1-332. DOI: 10.1016/j.icrp.2007.10.003. View

2.
Lee C, Kim K, Bolch W, Moroz B, Folio L . NCICT: a computational solution to estimate organ doses for pediatric and adult patients undergoing CT scans. J Radiol Prot. 2015; 35(4):891-909. DOI: 10.1088/0952-4746/35/4/891. View

3.
Dieckmeyer M, Sollmann N, Kupfer K, Loffler M, Paprottka K, Kirschke J . Computed Tomography of the Spine : Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose. Clin Neuroradiol. 2022; 33(2):271-291. PMC: 10220150. DOI: 10.1007/s00062-022-01227-1. View

4.
Sensakovic W, ODell M, Agha A, Woo R, Varich L . CT Radiation Dose Reduction in Robot-assisted Pediatric Spinal Surgery. Spine (Phila Pa 1976). 2016; 42(7):E417-E424. DOI: 10.1097/BRS.0000000000001846. View

5.