Automatic Detection of Respiration Rate from Ambulatory Single-lead ECG

Overview
Date 2009 Sep 25
PMID 19775978
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Ambulatory electrocardiography is increasingly being used in clinical practice to detect abnormal electrical behavior of the heart during ordinary daily activities. The utility of this monitoring can be improved by deriving respiration, which previously has been based on overnight apnea studies where patients are stationary, or the use of multilead ECG systems for stress testing. We compared six respiratory measures derived from a single-lead portable ECG monitor with simultaneously measured respiration air flow obtained from an ambulatory nasal cannula respiratory monitor. Ten controlled 1-h recordings were performed covering activities of daily living (lying, sitting, standing, walking, jogging, running, and stair climbing) and six overnight studies. The best method was an average of a 0.2-0.8 Hz bandpass filter and RR technique based on lengthening and shortening of the RR interval. Mean error rates with the reference gold standard were +/-4 breaths per minute (bpm) (all activities), +/-2 bpm (lying and sitting), and +/-1 breath per minute (overnight studies). Statistically similar results were obtained using heart rate information alone (RR technique) compared to the best technique derived from the full ECG waveform that simplifies data collection procedures. The study shows that respiration can be derived under dynamic activities from a single-lead ECG without significant differences from traditional methods.

Citing Articles

SolunumWear: A smart textile system for dynamic respiration monitoring across various postures.

Cay G, Solanki D, Al Rumon M, Ravichandran V, Fapohunda K, Mankodiya K iScience. 2024; 27(7):110223.

PMID: 39040071 PMC: 11261107. DOI: 10.1016/j.isci.2024.110223.


Estimating Heart Rate and Respiratory Rate from a Single Lead Electrocardiogram Using Ensemble Empirical Mode Decomposition and Spectral Data Fusion.

Chung I, Yu J, Hu W Sensors (Basel). 2021; 21(4).

PMID: 33567575 PMC: 7915478. DOI: 10.3390/s21041184.


Estimation of the Respiratory Rate from Localised ECG at Different Auscultation Sites.

Bao X, Abdala A, Kamavuako E Sensors (Basel). 2020; 21(1).

PMID: 33375588 PMC: 7796076. DOI: 10.3390/s21010078.


Wearable Respiration Monitoring: Interpretable Inference With Context and Sensor Biomarkers.

Alam R, Peden D, Lach J IEEE J Biomed Health Inform. 2020; 25(6):1938-1948.

PMID: 33147151 PMC: 8238391. DOI: 10.1109/JBHI.2020.3035776.


Application of Modern Multi-Sensor Holter in Diagnosis and Treatment.

Vavrinsky E, Subjak J, Donoval M, Wagner A, Zavodnik T, Svobodova H Sensors (Basel). 2020; 20(9).

PMID: 32392697 PMC: 7273207. DOI: 10.3390/s20092663.