» Articles » PMID: 38774368

Photoplethysmography and Intracardiac Pressures: Early Insights from a Pilot Study

Abstract

Aims: Invasive haemodynamic monitoring of heart failure (HF) is used to detect deterioration in an early phase thereby preventing hospitalizations. However, this invasive approach is costly and presently lacks widespread accessibility. Hence, there is a pressing need to identify an alternative non-invasive method that is reliable and more readily available. In this pilot study, we investigated the relation between wrist-derived photoplethysmography (PPG) signals and the invasively measured pulmonary capillary wedge pressure (PCWP).

Methods And Results: Fourteen patients with aortic valve stenosis who underwent transcatheter aortic valve replacement with concomitant right heart catheterization and PPG measurements were included. Six unique features of the PPG signals [heart rate, heart rate variability, systolic amplitude (SA), diastolic amplitude, crest time (CT), and large artery stiffness index (LASI)] were extracted. These features were used to estimate the continuous PCWP values and the categorized PCWP (low < 12 mmHg vs. high ≥ 12 mmHg). All PPG features resulted in regression models that showed low correlations with the invasively measured PCWP. Classification models resulted in higher performances: the model based on the SA and the model based on the LASI both resulted in an area under the curve (AUC) of 0.86 and the model based on the CT resulted in an AUC of 0.72.

Conclusion: These results demonstrate the capability to non-invasively classify patients into clinically meaningful categories of PCWP using PPG signals from a wrist-worn wearable device. To enhance and fully explore its potential, the relationship between PPG and PCWP should be further investigated in a larger cohort of HF patients.

Citing Articles

A scoping review on advancements in noninvasive wearable technology for heart failure management.

Scholte N, van Ravensberg A, Shakoor A, Boersma E, Ronner E, de Boer R NPJ Digit Med. 2024; 7(1):279.

PMID: 39396094 PMC: 11470936. DOI: 10.1038/s41746-024-01268-5.

References
1.
Gilotra N, Tedford R, Wittstein I, Yenokyan G, Sharma K, Russell S . Usefulness of Pulse Amplitude Changes During the Valsalva Maneuver Measured Using Finger Photoplethysmography to Identify Elevated Pulmonary Capillary Wedge Pressure in Patients With Heart Failure. Am J Cardiol. 2017; 120(6):966-972. DOI: 10.1016/j.amjcard.2017.06.029. View

2.
Mace M . A Novel Multisensor Device for Absolute Intracardiac Pressure Measurement, Detection, and Management of Heart Failure. JACC Basic Transl Sci. 2023; 8(4):377-379. PMC: 10149644. DOI: 10.1016/j.jacbts.2023.02.001. View

3.
Cunningham J, Di Achille P, Morrill V, Weng L, Choi S, Khurshid S . Machine Learning to Understand Genetic and Clinical Factors Associated With the Pulse Waveform Dicrotic Notch. Circ Genom Precis Med. 2022; 16(1):e003676. PMC: 9975074. DOI: 10.1161/CIRCGEN.121.003676. View

4.
Kovacs G, Avian A, Pienn M, Naeije R, Olschewski H . Reading pulmonary vascular pressure tracings. How to handle the problems of zero leveling and respiratory swings. Am J Respir Crit Care Med. 2014; 190(3):252-7. DOI: 10.1164/rccm.201402-0269PP. View

5.
Savarese G, Becher P, Lund L, Seferovic P, Rosano G, Coats A . Global burden of heart failure: a comprehensive and updated review of epidemiology. Cardiovasc Res. 2022; 118(17):3272-3287. DOI: 10.1093/cvr/cvac013. View