» Articles » PMID: 28754567

Usefulness of Pulse Amplitude Changes During the Valsalva Maneuver Measured Using Finger Photoplethysmography to Identify Elevated Pulmonary Capillary Wedge Pressure in Patients With Heart Failure

Overview
Journal Am J Cardiol
Date 2017 Jul 30
PMID 28754567
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The pulse amplitude ratio, the ratio of pulse pressure at the end of a Valsalva maneuver to before the onset of Valsalva, correlates with filling pressure. This study aimed to noninvasively estimate cardiac filling pressure in patients with heart failure. We developed a noninvasive handheld device to measure pulse amplitude ratio using finger photoplethysmography. In 69 patients who underwent right heart catheterization, photoplethysmography waveforms were recorded during a standardized Valsalva maneuver, and in 60 of these patients, pulse amplitude ratio was able to be calculated. Pulse amplitude ratio correlated with pulmonary capillary wedge pressure (PCWP) (r = 0.58, p <0.0001), particularly among those subjects with reduced ejection fraction (r = 0.60, p = 0.002, n = 25). A multivariable linear regression model for PCWP including pulse amplitude ratio, age, body mass index, systolic blood pressure, diastolic blood pressure, and heart rate yielded an R of 0.54. Difference in mean pulse amplitude ratio for subjects with a PCWP ≤15 mm Hg versus >15 mm Hg was statistically significant (p <0.0001, area under receiver operating characteristics curve 0.79 [0.66, 0.92]). Pulse amplitude ratio ≥0.55 predicted PCWP >15 mm Hg with 73% sensitivity and 77% specificity. Pulse amplitude ratio also increased by an average of 0.03 with a leg raise maneuver (p = 0.05, n = 36). In conclusion, we demonstrate that noninvasively measured response to the Valsalva maneuver in patients with HF can estimate PCWP and also detect changes within a single patient.

Citing Articles

Contemporary Review of Hemodynamic Monitoring in the Critical Care Setting.

Rali A, Butcher A, Tedford R, Sinha S, Mekki P, Van Spall H US Cardiol. 2024; 16:e12.

PMID: 39600839 PMC: 11588176. DOI: 10.15420/usc.2021.34.


Photoplethysmography and intracardiac pressures: early insights from a pilot study.

Scholte N, van Ravensberg A, Edgar R, van den Enden A, Van Mieghem N, Brugts J Eur Heart J Digit Health. 2024; 5(3):379-383.

PMID: 38774368 PMC: 11104463. DOI: 10.1093/ehjdh/ztae020.


Noninvasive Point of Care Device for Assessing Cardiac Response to Acute Volume Changes.

Silber H, Gilotra N, Miller T Med Devices (Auckl). 2023; 16:219-227.

PMID: 37908436 PMC: 10614661. DOI: 10.2147/MDER.S416845.


The answer at our fingertips: Volume status in cirrhosis determined by machine learning and pulse oximeter waveform.

Mazumder N, Kazen A, Carek A, Etemadi M, Levitsky J Physiol Rep. 2022; 10(5):e15223.

PMID: 35274819 PMC: 8915710. DOI: 10.14814/phy2.15223.